background image

1

Sales 800-633-0405

www.productivity2000.com

Terminal Block sold separately, (see wiring options on page 5).

Warranty: Thirty-day money-back guarantee. Two-year limited 

replacement. (See www.productivity2000.com for details).

®

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and to 

verify that the equipment, installation, and operation are in compliance with 

the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the 

failure to follow all applicable codes and standards. We do not guarantee 

the products described in this publication are suitable for your particular 

application, nor do we assume any responsibility for your product design, 

installation, or operation.

If you have any questions concerning the installation or operation of 

this equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time 

it was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

Removable Terminal Block Specifications

Part Number

P2-RTB

P2-RTB-1

Number of  

positions

18 Screw Terminals

18 Spring Clamp Terminals

Wire Range

30–16 AWG (0.051–1.31 mm²)
Solid / Stranded Conductor
3/64 in. (1.2 mm) Insulation Maximum
1/4 in (6–7 mm) Strip Length

28–16 AWG (0.081–1.31 mm²)
Solid / Stranded Conductor
3/64 in (1.2 mm) Insulation Maximum
19/64 in (7–8 mm) Strip Length

Conductors

“USE COPPER CONDUCTORS, 75ºC” or equivalent.

Screw Driver 

Width

0.1 in (2.5 mm) Maximum*

Screw Size

M2

N/A

Screw Torque

2.5 lb·in (0.28 N·m)

N/A

P2-08ADL-2 Analog Input

The P2-08ADL-2 Low Resolution Voltage Analog 

Input  Module provides eight channels for receiving 

0–10 VDC signals for use with the Productivity2000 

System. 

Warning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Removable Terminal Block Specifications. . . . . . . .  1

General Specifications   . . . . . . . . . . . . . . . . . . . . . . 2

Input Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . 2

Wiring Diagram and Schematic . . . . . . . . . . . . . . . . 3

Module Installation Procedure . . . . . . . . . . . . . . . . . 4

QR Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Hot Swap Information  . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Module Configuration   . . . . . . . . . . . . . . . . . . . . . . . 5

Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Non-Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . 6

*Recommended Screwdriver TW-SD-MSL-1

Summary of Contents for Productivity 2000 P2-08ADL-2

Page 1: ...s available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block Specifications Part...

Page 2: ...ained at www productivity2000 com Terminal Type 18 position Removable Terminal Block Weight 100g 3 5 oz Input Specifications Input Channels 8 Module Signal Input Range 0 10 VDC Resolution 13 bit Data Range 0 8191 counts Input Type Single ended 1 common Resolution Value of LSB 0 10 VDC 1 22 mV per count 1 LSB 1 Count Maximum Continuous Overload 100VDC Input Impedance 150kΩ Filter Characteristics Lo...

Page 3: ...C CH7 ADC CH8 ADC ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY 1 2 3 4 5 6 7 8 9 10 11 12 18 13 14 15 16 17 24 VDC User Supplied Power Voltage Input Circuits 3 Wire Voltage Transmitter V COM 3 Wire Transmitter 4 Wire Transmitter COM V 4 Wire Voltage Transmitter Transmitter Power Supply AC or DC V7 COM V8 Notes for maximum accuracy 1 Jumper unsused inputs t...

Page 4: ...an your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mo...

Page 5: ...lected and to each Status Bit Item Wiring Options 1 ZIPLink Feed Through Modules and Cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL RTB20 ZL RTB20 1 ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL P2 CBL18 1P ZL P2 CBL18 2P 3 Screw Terminal Block only P2 RTB Quantity 1 4 Spring Clamp Terminal Block only P2 RTB 1...

Page 6: ...1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Enter values for each breakpoint in the table Each breakpoint will define a segment of the non linear scaling 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 The Scale Linear function can be used to Convert analog field input signals from the range which is native to the analog input module to an application specific range Make other l...

Page 7: ...7 Sales 800 633 0405 www productivity2000 com ...

Page 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 08ADL 2 DS 3rd Ed 8 20 2019 Copyright 2016 AutomationDirect com Incorporated All Rights Reserved Worldwide ...