Select the Input and Output tags appropriate 

for the application. Convert raw input signals 

to engineering units for use in the program, or 

convert engineering units to output signals for 

control purposes 

max 

 

 

 

 

 

 

 

min 

min 

 

max 

12500

0

65535

220

Level Transmitter

Tank Level

0

.5

1

1.55

2.25

3

4.55

6.75

7

0

0

0

0

0

0

0

0

1

2

3

4

5

6

6.5

7

0

0

0

0

0

0

0

Level Transmitter

Tank Level

7

0

0

0

0

0

0

0

Enter values for each breakpoint in the 

table. Each breakpoint will define a 

segment of the non-linear scaling.

7
6
5
4
3
2
1
0

1   2   3   4   5   6   7   8   9  

The Scale (Linear) function can be used to:
• Convert analog field input signals from the range which is native to the 

analog input module to an application specific range.

• Make other linear conversions in ranges appropriate to the application.

The Scale (Non-Linear) function can be used for Non-Linear applications.

Linear Scaling

Non-Linear Scaling

 8191

Summary of Contents for Productivity 2000 P2-08ADL-2

Page 1: ...s available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block Specifications Part...

Page 2: ...ained at www productivity2000 com Terminal Type 18 position Removable Terminal Block Weight 100g 3 5 oz Input Specifications Input Channels 8 Module Signal Input Range 0 10 VDC Resolution 13 bit Data Range 0 8191 counts Input Type Single ended 1 common Resolution Value of LSB 0 10 VDC 1 22 mV per count 1 LSB 1 Count Maximum Continuous Overload 100VDC Input Impedance 150kΩ Filter Characteristics Lo...

Page 3: ...C CH7 ADC CH8 ADC ISOLATED ANALOG CIRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY 1 2 3 4 5 6 7 8 9 10 11 12 18 13 14 15 16 17 24 VDC User Supplied Power Voltage Input Circuits 3 Wire Voltage Transmitter V COM 3 Wire Transmitter 4 Wire Transmitter COM V 4 Wire Voltage Transmitter Transmitter Power Supply AC or DC V7 COM V8 Notes for maximum accuracy 1 Jumper unsused inputs t...

Page 4: ...an your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mo...

Page 5: ...lected and to each Status Bit Item Wiring Options 1 ZIPLink Feed Through Modules and Cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL RTB20 ZL RTB20 1 ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL P2 CBL18 1P ZL P2 CBL18 2P 3 Screw Terminal Block only P2 RTB Quantity 1 4 Spring Clamp Terminal Block only P2 RTB 1...

Page 6: ...1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Enter values for each breakpoint in the table Each breakpoint will define a segment of the non linear scaling 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 The Scale Linear function can be used to Convert analog field input signals from the range which is native to the analog input module to an application specific range Make other l...

Page 7: ...7 Sales 800 633 0405 www productivity2000 com ...

Page 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 08ADL 2 DS 3rd Ed 8 20 2019 Copyright 2016 AutomationDirect com Incorporated All Rights Reserved Worldwide ...

Reviews: