background image

8

Tech Support 770-844-4200

www.productivity1000.com

Document Name

Edition/Revision

Date

P1-4ADL2DAL-1-DS

1st Edition

5/18/2018

Copyright 2018, AutomationDirect.com Incorporated/All Rights Reserved Worldwide

 Terminal Block Specifications

Part Number

P1-10RTB

P1-10RTB-1

Positions

10 Screw Terminals

10 Spring Clamp Terminals

Wire Range

30–16 AWG (0.051–1.31 mm²)
Solid / Stranded Conductor
3/64 in (1.2 mm) Insulation Max.
1/4 in (6–7 mm) Strip Length

28–16 AWG (0.081–1.31 mm²)
Solid / Stranded Conductor
3/64 in (1.2 mm) Insulation Max.
19/64 in (7–8 mm) Strip Length

Conductors

“USE COPPER CONDUCTORS, 75ºC” or equivalent.

Screw Driver

0.1 in (2.5 mm) Maximum*

Screw Size

M2

N/A

Screw Torque

2.5 lb·in (0.28 N·m)

N/A

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and 

to verify that the equipment, installation, and operation are in compliance 

with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from 

the failure to follow all applicable codes and standards. We do not 

guarantee the products described in this publication are suitable for 

your particular application, nor do we assume any responsibility for your 

product design, installation, or operation.

If you have any questions concerning the installation or operation of 

this equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time 

it was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

*Recommended Screw Driver TW-SD-MSL-1

8

Tech Support 770-844-4200

www.productivity1000.com

Summary of Contents for Productivity 1000 P1-4ADL2DAL-1

Page 1: ...wiring options on page 5 General Specifications Operating Temperature 0º to 60ºC 32º to 140ºF Storage Temperature 20º to 70ºC 4º to 158ºF Humidity 5 to 95 non condensing Environmental Air No corrosive gases permitted Vibration IEC60068 2 6 Test Fc Shock IEC60068 2 27 Test Ea Field to Logic Side Isolation 1800VAC applied for 1 second Insulation Resistance 10M 500VDC Heat Dissipation 2470mW Enclosur...

Page 2: ...ontinuous Overload Outputs open circuit protected Type of Output Protection Electronically current limited to 20mA or less Output Signal at Power Up and Power Down 4mA Input Specifications Inputs per Module 4 Module Signal Input Range 0 20 mA Signal Resolution 13 bit Resolution Value of LSB least significant bit 0 20 mA 2 44 µA per count 1LSB 1 count Data Range 0 8191 counts Input Type Sinking Sin...

Page 3: ...CUIT POWER P1 4ADL2DAL 1 Wiring Diagram Current Input Circuits Current Output Circuits COM 3 Wire Current Transmitter 032A 2 Wire 4 20 mA Transmitter fuse 2 Wire Transmitter 3 Wire Transmitter 24VDC User Supplied Power 032A fuse Note Do not connect both ends of shield 4 Wire 4 20 mA Transmitter 4 Wire Transmitter User Supplied Transmitter Power AC or DC 4 20mA Load Note Shield is connected to comm...

Page 4: ...cked position and then pull modules apart Step Two Attach field wiring using the removable terminal block or ZIPLink wiring system LOCK UNLOCK WIRE STRIP LENGTH MIN MAX P1 08TD1 Check all latches are secure after modules are connected QR Code Use any QR Code reader application to display the module s product insert P1 08TD1 P1 08TD1 1 2 3 4 5 6 7 8 9 10 L L L L L L L L 24V 1 2 3 4 0V 5 6 7 8 12 24...

Page 5: ...nly P1 10RTB Quantity 1 4 Spring Clamp Terminal Block only P1 10RTB 1 Quantity 1 5 Accessories ZL RTB COM TW SD SL 1 TW SD MSL 2 ZL RTB20 ZL RTB20 1 2 1 Cable ZIPLink Module Complete System 2 ZL RTB COM provides a common connection point for power or ground Complete System ti i t f Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software drag and dr...

Page 6: ... raw input signals to engineering units for use in the program or convert engineering units to output signals for control purposes max min min max 1045 0 8191 220 Level Transmitter Tank Level Non Linear Scaling Non Linear Scalin 0 5 1 1 55 2 25 3 4 55 6 75 7 0 0 0 0 0 0 0 0 1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw...

Page 7: ...7 Sales 800 633 0405 www productivity1000 com ...

Page 8: ... determine which codes should be followed and to verify that the equipment installation and operation are in compliance with the latest revision of these codes Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular application nor do we a...

Reviews: