In
sta
lla
tio
n
an
d
S
pe
cif
ic
ati
on
s
Choosing
Connecting Cables
Depending on which PLC you are
using, you may require as many as
two
cables.
Here
are
the
requirements:
D
OP-ACBL-1:
all
units require
this cable for configuration. This
is a 9-pin female to 15-pin male
cable
that
connects
your
personal
computer
to
the
OP-panel. This cable is also
used to connect an OP-panel to
the Allen-Bradley SLC 500
CPUs.
D
CPU Cables:
You will also need
the appropriate cable to connect
your CPU to the OP-panel. Use
the chart shown to the right to
choose
the
correct
communications cable.
OP-9001 Cable Connectors
If you’re planning to use multiple
panels and an OP-9001, then you’ll
need to build your own custom
cables. Since the proper cable
choice really depends on your
application, we offer the following
connectors.
D
OP-CMCON--1
—
pack of 4
ribbon cable connectors.
D
OP-CMCON--2
—
pack of 4
solder-type connectors.
D
OP-CMCON--3
—
pack of 2
D--shell connectors with screw
terminals for use with OP
-
9001
& multiple OP-panels.
D
OP-PSCON
—
pack of 4 power
supply block connectors.
For electrically noisy environments,
we recommend an individually paired
and shielded cable, such as Belden
9729 or equivalent. This type of cable
will require the solder-type or D-shell
with screw terminal connectors. If
you’re going 30 feet or less, you can
use ribbon cable. For ribbon cable,
we recommend Belden 9L28015 or
3M 3365/15.
**
--
also available in DC versions
*
— requires RS232 Data Communications Unit (D3--232--DCU)
2--5
Installation and Specifications
OptiMate Cables
Family
CPU
(or other device)
Port
Cable
Family
CPU
(or other device)
Port
Cable
Direct
LOGIC
t
DL05 / DL105
DL05: D0--05
DL105: DL130
DL05: Both ports
DL105: Only one port
OP--2CBL
Direct
LOGIC
t
DL205
DL230
Only port
OP--2CBL
DL205
DL240
Top port
OP--2CBL
Bottom port
OP--2CBL
DL250
Top port
OP--2CBL
Bottom port
OP--2CBL--1
D2--DCM (module)
Only port
OP-4CBL--2
Direct
LOGIC
t
DL305
DL330
Requires DCU*
OP--4CBL--2
DL305
DL330P
Requires DCU*
OP-4CBL--2
DL340
Top port
OP-3CBL
Bottom port
OP-3CBL
DL350
Top port
OP-2CBL
Bottom port
OP-4CBL-2
Direct
LOGIC
t
DL405
DL430
Top port (15-pin)
OP-4CBL--1
DL405
Bottom port (25-pin)
OP-4CBL--2
DL440
**
Top port
OP-4CBL--1
DL440
**
Bottom port
OP-4CBL--2
DL450**
Phone Jack
OP-2CBL
Top port (15-pin)
OP-4CBL--1
Bottom port (25-pin)
OP-4CBL--2
D4--DCM (module)
Only port
OP-4CBL--2
Slice I/O panels
Only port
OP-4CBL--1
GE
â
Series 1
IC610CPU105/106
Requires DCU*
OP-4CBL--2
TI305
t
/
SIMATIC
â
TI305
t
325--07, PPX:325--07
Requires DCU*
OP-4CBL--2
SIMATIC
â
TI305
t
330--37, PPX:330--37
Requires DCU*
OP-4CBL--2
325S--07 (or 325 w/ Stage Kt)
Requires DCU*
OP-4CBL--2
330S--37, PPX:330S--37
Requires DCU*
OP-4CBL--2
335--37, PPX:335--37
Phone Jacks
OP-3CBL
If DCU is used*
OP-4CBL--2
TI405
t
/
SIMATIC
â
TI405
t
425--CPU, PPX:425--CPU **
Only port
OP-4CBL--1
SIMATIC
â
TI405
t
PPX:430--CPU
Top port (15-pin)
OP-4CBL--1
Bottom port (25-pin)
OP-4CBL--2
435--CPU, PPX:435--CPU **
Top port (15-pin)
OP-4CBL--1
Bottom port (25-pin)
OP-4CBL--2
Smart Slice
t
I/O panels
Only port
OP-4CBL--1
A--B SLC 500
5/03, 5/04
Bottom port
OP-ACBL--1
A-B
MicroLogix
Only port
OP-ACBL--2