C2-02CPU Quick Start Guide 

Copyright© 2020, 

Automationdirect.com

 Incorporated/All Rights Reserved Worldwide

FCC and ISED Regulatory Statements

The C2-02CPU has achieved modular radio certification on 
a reference design for the United States and Canada . The 
reference design has been certified for Part 15.247 (Intentional 
Radiator) of the FCC rules and regulations, Industry Canada 
RSS-210.

Per FCC 15.19(a)(3) and (a)(4) This device complies with 
part 15 of the FCC Rules. Operation is subject to the follow-
ing two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference 
received, including interference that may cause undesired 
operation.

Note: This equipment has been tested and found to comply 
with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own 
expense.

The C2-02CPU complies with Part 15.247 modular (Inten-
tional Radiator) FCC rules and regulations. Changes or mod-
ifications not expressly approved by AutomationDirect could 
void the user’s authority to operate the equipment. 

Per RSS-Gen, Section 8.4 this device complies with Industry 
Canada license-exempt RSS standard(s). Operation is subject 
to the following two conditions: (1) this device may not cause 
interference, and (2) this device must accept any interference, 
including interference that may cause undesired operation of 
the device.

Par RSS-Gen, Section 8.4 cet appareil est conforme à la norme 
RSS Industrie Canada exempt de licence. Son fonctionnement 
est soumis aux deux conditions suivantes: (1) cet appareil 
ne doit pas provoquer d’interférences et (2) cet appareil doit 
accepter toute interférence, y compris les interférences pouvant 
causer un mauvais fonctionnement du dispositif.

Accessories

SE-ANT210

Whip/straight  

2.4 GHz antenna, 

IP65, connector 

mount.

SE-ANT250

Dome  

2.4 GHz antenna,  

IP67, panel mount,  

9.8ft/3m cable length.

C2-FILL

Snap-on CPU Option 
Slot cover for applications 
without an Option Slot 
module present.

C0-4TB

Replacement terminal 
block for the 24VDC 
power connection.  
Sold in packs of 2.

D0-MC-BAT

Replacement battery for 
CLICK PLUS CPU units.

Summary of Contents for CLICK PLUS C2-02CPU

Page 1: ...ICK PLUS CPU PC or Android or iOS mobile device for setup provisioning Click Software ver 3 00 or later PC or Click App mobile device 24VDC power supply SELV and Limited Energy CLICK power supply C0 00AC or C0 01AC is recommended Appropriate enclosure with vertical surface for DIN rail or surface mount M4 screws spring washers and flat washers if surface mounting Ferrules and crimping tool for wir...

Page 2: ...ent may be invalidated CAUTION For use in Pollution Degree 2 Environment Use and store the equipment in an environment described in the specifications regarding temperature humidity vibrations shock etc in order to avoid equipment damage or fire Ensure all wiring has strain reliefs in order to avoid damage to insulation that might result in electric shock or fire Ensure secondary external power ci...

Page 3: ...the 4 pin connector located on the bottom of the CPU unit 16 28 AWG wiring is supported We recommend using crimping ferrules on all wire terminations for a more secure connection The following crimping ferrules are recommend ed for the 24VDC power terminals Company Type Model No Compliant Wire AutomationDirect Ferrule V30AE000009 V30AE000041 0 2 0 5 mm2 22 26AWG Maximum tightening torque is 0 22 t...

Page 4: ...e module into its slot Press the module into place until it is fully seated 3 Push the top and bottom locking clips backward until they click into place Lift slightly on the locking clips until they release then slide each clip forward Reverse the procedure To install an Option Slot Module To install an Option Slot Module To remove an Option Slot Module To remove an Option Slot Module 3 Push the t...

Page 5: ...r SE ANT250 A remote mounted antenna is recommended to connect with the enclosure closed PREPARE A MOBILE DEVICE FOR CONNECTION Install the CLICK PLUS Provisioning App using one of the QR codes below or search for the app in the appropri ate app store CLICK PLUS Provisioning published by Automationdirect com FIND THE NEW CPU Connect to the CPU as follows 1 Open the CLICK PLUS Provisioning App 2 Ta...

Page 6: ... need to connect SET UP NETWORK PARAMETERS 9 Once the PLC is connected to the wireless access point or wired network choose which IP address configuration to use then tap Next to continue 9a Use DHCP Automatically assign a network IP address to the CLICK PLUS PLC This is often the simplest way to connect 9b Use Default Fixed Address Wireless 192 168 0 11 Wired 192 168 0 10 9c Use the following IP ...

Page 7: ...g No Error Off Blink WLAN LED Green On Link Activity No Link Off Blink POWER LED Green On Power Good USB Low Power Mode Power Failure Off Blink RUN LED Green On CPU Run Mode Initializing Analog Module CPU Program Mode Off Blink LED Status Indicators Connecting via USB To connect the CLICK PLUS CPU to a PC use a USB A to USB micro B cable such as the AutomationDirect USB CBL AMICB6 cable 1 Connect ...

Page 8: ...0 MC BAT recommended Technical Specifications Power Specifications Power Input Voltage Range 20 28 VDC Class 2 or SELV Safety Extra Low Voltage or Limited Energy Circuit power supply Maximum Power Consumption 20W Maximum Inrush Current 30A 1ms Acceptable External Power Drop Max 10ms AC Power Failure with C0 00AC or C0 01AC Wire Range 16 28 AWG Wire Strip Length 7 0 mm Wire Specification Lead free ...

Page 9: ...0 Automationdirect com Incorporated All Rights Reserved Worldwide Mechanical Drawings Unit Dimensions mm in BLUETOOTH PAIRING MODE SWITCH MICRO USB POWER TERMINAL BLOCK OPTIONAL MODULE SLOT ANTENNA STATUS LED s 101 8 4 01 85 0 3 35 46 6 1 83 46 4 1 83 FULLY EXTENDED OVERALL 53 5 2 11 60 8 2 39 32 3 1 27 126 8 4 99 PART NO SE ANT210 ...

Page 10: ...mmunications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The C2 02CPU complies with Part 15 247 modular Inten tional Radiator FCC rules and regulations Changes or mod ifications not expressly approved by AutomationDirect could void the user s authority to operate the...

Reviews: