background image

 
 
 

The

 

QNix® 7500

 coating thickness measuring gauge is part 

of the product line of non-destructive measurement gauges. 
Designed for the future, this modular system gauge is cha-
racterized  by  a  wide  application  range  and  a  robust  build, 
already well known from our other gauges. It is possible for 
example to use the 

QNix® 7500

 with an integrated probe as 

a  one-hand  operated  gauge,  or  by  using  a  connecting  ca-
ble, as a gauge with an external probe. Using the respective 
probe, the gauge will measure coatings on steel and iron or 
coatings  on  a  non-magnetic,  metallic  substrate  such  as 
aluminium. 
Please  read  these  instructions  carefully  before  operating 
the gauge for the first time. It will help you to make use of all 
advantages and conveniences the 

QNix® 7500

 has to offer. 

 
Would you like to know more about the other coating thick-
ness gauges of our product line? Or do you have any ques-
tions  concerning  coating  thickness  measuring?  Please  do 
not  hesitate  to  contact  us.  Our  specialists  with  their  long-
standing experience will be glad to assist you. 
 
 
 
 
 
 
 
The 

QNix®  7500

  coating  thickness  measuring  gauge  is  a 

combination  gauge  with  a  wide  range  of  applications.  Op-
tionally, it is available with memory and statistical functions 
(

QNix® 7500 M)

The  basic  gauge  can  be  combined  with  an  integrated  Fe-, 
NFe-  or  dual-probe.  If  the  gauge  shall  be  used  with  an  ex-
ternal  probe,  just  pull  the  probe  out  of  the  gauge  and  con-
nect the probe with the optionally available adapter cable. 
The Fe-probe measures all non-magnetic coatings such as 
lacquer,  powder  coatings,  plastic,  enamel,  chromium,  cop-
per, zinc, etc. on steel or iron. 
The  NFe-probe  measures  all  insulating  coatings  such  as 
lacquer,  plastic,  enamel,  etc.  on  non-magnetic  substrates 
such as aluminium, copper, brass or stainless steel. 
With  the  integrated  interface  readings  can  be  transferred 
online to a computer (serial-port or USB-port). 
The 

QNix® 7500 M

 coating thickness measuring gauge can 

be supplied with memory to store readings and even subdi-
vide  them  into  blocks.  Up  to  3900  readings  can  be  stored.  
As  a  further  option,  an  evaluation  software  for  statistical 
evaluation and documentation can be supplied. 
The 

QNix®  7500

  complies  to  national  and  international 

(DIN, ISO, BS, ASTM) standards and regulations: 
 
 

 

DIN 50981, 50984 

 

 

ISO 2178, 2360, 2808 

 

 

BS 5411 (3 & 11), 3900-C5 

 

 

ASTM B499, D 7091 

 
 
 
 
 

The 

QNix® 7500

 incorporates the latest electronic technol-

ogy  in  order  to  fulfill  different  measuring  tasks.  This  high 
precision  instrument  covers  a  wide  range  of  applications, 
yet it is robust and easy-to-use in every-day practice. If op-
erated  and  treated  with  care,  it  will  serve  you  many  years 
producing accurate and reliable readings. 
Do  not  let  it  drop  and  protect  it  from  dirt,  dust  and  other 
substances.  Protect  the  gauge  from  moisture,  chemically 
aggressive substances and/or gases. 
After use, the gauge should be stored in its protective carry-
ing case. 

Substantial changes in temperature can influence the read-
ings,  as  is  the  case  with  all  precision  gauges.  Do  not  ex-
pose the gauge to strong, direct sunlight or to other sources 
of energy causing temperature shocks. 
The  housing  is  resistant  against  most  solvents.  However  a 
resistance against all chemical substances cannot be guar-
anteed. Use only a damp, soft cloth to clean the housing. 
Accurate  readings  can  only  be  obtained,  if  the  measuring 
probe is clean. Check the probe regularly and remove resi-
dues such as lacquer etc. from the ruby tip. 
If the gauge will not be used for a longer period, remove the 
battery  in  order  to  prevent  leakage  and  therefore  destruc-
tion of the gauge. 
In case of malfunction, please do not try to repair the gauge 
yourself.  Our  repair  service  will  be  glad  to  assist  at  any 
time. 
 
 
 
 
 
 
 
The standard probes have a measuring range of 
0-2000 µm or 0-80 mil (1 mil = 25.4 µm) 
Optionally probes with a measuring range of up to 5000 µm 
(200 mil) and right-angle-probes are also available. 
The 

QNix®  7500

  is  operating  either  in  µm  or  in  mil  only. 

The  unit  is  preset  before  shipping  depending  on  the  desti-
nation country. 

G

auges with memory 

QNix® 7500 M

 can be 

switched  from  µm  to  mil  using the optionally available soft-
ware. 
The resolution depends on the thickness of the coating and 
is as follows: 
 
0.1 µm in the range of 0.0 - 99.9 µm 
1 µm in the range of 100 - 999 µm 
0.01 mm in the range of 1.00 - 2.00 (5.00) mm 
or 
0.01 mil in the range of 0.00 - 9.99 mil 
0.1 mil in the range of 10.0 - 80 (100) mil 
(1 mil in the range of 100 - 200 mil) 

 
 

 
 
Storage:  

-10°C - 60°C (14°F - 140 °F) 

Operating: 

   0°C - 50°C (32°F - 122 °F) 

 
 
 
 
 
 
 
The 

QNix®  7500

  is  powered  by  a  9V  alkaline  battery.  The 

battery  is  located  at  the  bottom  end  of  the  gauge.  If  the 
blinking sign "BAT" appears in the display, it is advisable to 
change  the  battery.  However  it  is  still  possible  to  measure 
for some time. Stored data will not be deleted when the bat-
tery is empty or while changing the battery. 
 
 
 
 
 
 
A  new  zero-adjustment  is  required  when  using  the  gauge 
for  the  first  time,  working  with  different  materials,  and  after 
inserting a new battery. 
Place  the  probe  of  the 

QNix®  7500

  on  one  of  the  zero 

plates  enclosed  in  the  case.  For  measurements  on  ferrous 
substrates use the steel zero plate, for non-ferrous applica-
tions  use  the  aluminium  plate  or  a  respective  uncoated 
substrate. 

Make sure the probe is placed rectangularly and evenly on 
the surface of the zero plate or on your uncoated substrate. 
If  the  value  indicated  is  not  within  the  basic  tolerance,  the 
gauge  should  be  adjusted  (gauges  with  memory 

QNix® 

7500 M

 must not be in the Memory Mode). Press the lower 

red button C of the gauge while the probe is placed on the 
zero  plate,  i.e.  the  substrate.  You  will  hear  a  "beep"  and  a 
control number will appear on the display. Lift the gauge or 
the probe at least 10 cm (4 inches) from the zero plate. The 
gauge  will  "beep"  again  and  another  number  will  be  dis-
played. Now the 

QNix® 7500

 is adjusted. 

When repeating measurements on the same spot, the read-
ings may not always be 0.00 µm/mil, as the surface rough-
ness, dirt, scratches etc. might cause differences. 
 
 
 
 
 
 
 
Place the probe evenly on the object to be measured. Place 
the thumb directly above the probe. This ensures best han-
dling.  The  reading  is  immediately  indicated  on  the  display, 
accompanied  by  a  "beep".  Simultaneously  you  will  also  re-
ceive  the  information,  which  probe, Fe or NFe,  is presently 
used in the gauge. 
The most obvious advantage of the modular system 

QNix® 

7500

  is  the  universal  application.  Fe-,  NFe-,  and  Dual-

Probes  can  be  plugged  firmly  into  the  housing  (internal 
probe)  or  attached  to  it  by  an 

QNix®  7500  adapter  cable

 

(external  probe).  In  order  to  measure  with  a  separate,  ex-
ternal  probe,  the  internal  probe  can  be  pulled  out  of  the 
housing. An optionally available 

QNix® 7500

 

adapter cable

 

with plug is inserted into the opening. Connect the probe to 
the plug of the cable. This versatile coating thickness gauge 
allows  measurements  even  on  hard-to-reach  spots  or  on 
difficult geometries. A special probe recognition system will 
automatically tell you, which probe you are presently using. 
If the 

QNix® 7500

 or its probe is placed incorrectly, the dis-

play shows "Err" (error). The same message appears when 
the  probe  is  lifted  before  the  measurement  has  been  com-
pleted  or  when  the  probe  is  zeroed  on  a  non-metallic  sub-
strate. 
If  the  measurements  are  out  of  range,  the  display  shows 
"InFi"  (infinite).  The  same  will  be  displayed,  if  measure-
ments on non-metallic substrates are taken. 
The gauge automatically turns on, when the probe is placed 
on the surface, and shuts off after approx. 10 sec, if it is not 
used.  The  last  reading  is  stored  and  appears  again  on  the 
display, when the upper right button M is pressed shortly. 
When  measuring  on  rod  materials  align  the  "V"-groove  in 
the ring of the probe with the rod. 
Do not take measurements on magnetized parts! 
Magnetic  fields  are  likely  to  influence  the  readings  of  the 
Fe-probe,  strong  electro-magnetic  fields  may  influence  all 
measurements. 
 
 
 
 
 
 
 
 
When  using  the  Dual  Probe,  switching  from  Fe-  to  NFe-
measurements or vice versa is done as follows: 
 
Switch  on  the 

QNix®  7500

.  The  actual  measuring  method 

Fe or NFe is displayed on the left side (e.g. Fe). Then press 
the  lower  left  button C for at least 3 seconds. A "beep" will 
sound and the new measuring method is shown on the left 
side  of  the  display  (e.g.  NFe).  To  switch  back  to  the  other 
method just press C again for 3 seconds. 
 
 

 
 
 
In  order  to  transfer  data,  the  gauge  has  to  be  connected 
through  the  optionally  available  interface  cable  with  the 
serial-port or the USB-port of a computer. To show the data 
online, our 

QNix

®

 software can be used or standard editing 

programs. 
 
 
 
 
 
 
 
 
 
Gauges with memory 

QNix® 7500 M

 are offering the follow-

ing features: 
 
a)   Storing up to 3900 readings 
b)   Block segmentation 
c)   Display of the mean value for each block

 

d)   Display of the maximum value of each block

 

e)   Display of the minimum of each block 
f)   Deleting the last reading or entire memory 
g)   Processing of the readings using the software 
 
 
 
 
 
 
When the 

QNix® 7500 M

 is switched on, the gauge is in the 

Normal Mode

 where no readings are stored. 

To activate the 

Memory

 

Mode

, press the upper right button 

M  for  approx.  1  second.  Measurements  in  the  Memory 
Mode  are  accompanied  by  a  double  "beep".  Approx.  2 
seconds  after  the  last  reading  has  been  taken  the  display 
starts alternating to show the reading and the number "N" of 
the  reading,  e.g.  the  display  shows  125  µm  (last  reading) 
and N 0014 (number of reading). 
If no readings are stored in the memory the display alternat-
ing shows b001 and the sign "bloc", indicating that the read-
ings will automatically be stored in block 1. 
To leave the Memory Mode, press the upper right button M 
again.  Notice:  If  pressed  longer  than  3  seconds,  a  new 
block will be created. 
The  built-in  memory  can  store  up  to  3900  readings.  If  the 
gauge  is  out  of  memory,  the  display  shows  "End"  for  ap-
prox.  6  seconds.  Then  the  last  reading  alternating  with  the 
number of this reading is shown. 
If no measurements are taken within 30 seconds, the gauge 
switches off. The gauge automatically returns to the Normal 
Mode if started again. 
 
 
 
 
 
 
 
 
In the Memory Mode the readings can be stored in different 
blocks, in order to distinguish the different tasks. Up to 999 
blocks  are  available.  In  order  to  create  a  new  block,  press 
the  upper  right  button  M  while  the  gauge  is  in  the  Memory 
Mode.  Wait  until  the  gauge  beeps  and  the  word  "bloc"  is 
shown,  alternating  with  the  number  of  the  new  block  (e.g. 
"b002"  for  block  no.  2).  Other  blocks  can  be  created  using 
the  same  procedure.  The  size  of  the  blocks  may  vary  as 
they are determined by the user only. If all 999 blocks have 
been  used,  the  display  shows  "End"  for  approx.  6  seconds 
and a beeping alarm sounds. 

    Introduction

 

    System Description

 

    Maintenance 

    Measuring Range 
    and Resolution

 

    Temperature Range

 

    Operation and 
    Battery Exchange

 

    Zero-Adjustment 

 

    Handling

 

    Measurements  
    with the Dual Probe

 

    Storing 
    Measured Values

 

    Block Segmentation 
    in the Memory Mode

 

    Memory Mode (optional)

 

     

Data Output with Interface 

 

Reviews: