background image

QR Code

Wiring Diagram and Schematic

12–24 VDC

+

12–24 VDC

+

C1

1
2
3
4

C2

5
6
7
8

123456789

10
11
12

18

13
14
15
16
17

+

+

 

www.productivity2000.com  

Tech Support 770-844-4200

 

Sales 800-633-0405 

www.productivity2000.com 

3

INPUT

COM

Internal Module Circuitry

Optical Isolator

12–24 VDC

+

Equivalent Input Circuit 

+

Important Hot-Swap Information

The Productivity2000 supports hot-swap! 

Individual 

modules can be taken offline, removed, and replaced 

while the rest of the system continues controlling your 

process. Before attempting to use the hot-swap feature, 

be sure to read the hot-swap topic in the programming 

software’s help file or our online documentation at 

AutomationDirect.com for details on how to plan your 

installation for use of this powerful feature.

Use any QR Code reader application to 

display the module’s product insert.

Caution: 

If possible, remove field power prior to  

proceeding. If not, then 

EXTREME

 care 

MUST 

be taken 

to prevent damage to the module, or even personal injury 

due to a short circuit from the live terminal block.