Menu 4. Lock times
Lock output can be programmed for both hold and pulse motor starting. The operation of the lock can be
programmed to activate prior to the gate and behave differently on open and close cycles.
Control Board Adjustments
Parameter
Min
Max
Default
Step
Unit
Menu No.
OPEN LOCK TIME Set the time the lock is
activated for on open cycles
0.0
Hold
0.5
0.1
Sec
4
CLOSE LOCK TIME Set the time the lock is
activated for on close cycles
0.0
Hold
0.5
0.1
Sec
4
PRE-OPEN LOCK TIME
Time the lock is activated for prior to opening
0.0
25.5
0.0
0.1
Sec
4
PRE-CLOSE LOCK TIME
Time the lock is activated for prior to closing
0.0
25.5
0.0
0.1
Sec
4
Menu 5. Light times
With the addition of a relay module connected to the control board, a light can be activated for a period prior
to the start and end of a drive cycle. The light is used to warn surrounding persons that the gate is about to be
activated.
Parameter
Min
Max
Default
Step
Unit
Menu No.
ON AFTER CYCLE LIGHT TIME
Time light remains on for after a cycle
0
255
60
1
Sec
5
ON BEFORE OPEN CYCLE LIGHT TIME
Minimum time light is activated for prior to
opening
0
255
0
1
Sec
5
ON BEFORE CLOSE CYCLE LIGHT TIME
Minimum time light is activated for prior to
closing
0
255
0
1
Sec
5
Menu 6. Motor settings
Motor speed
The maximum speed the motors run at is controlled by the MOTOR FULL SPEED VOLTAGE parameter. The
default value is the maximum recommended for normal operation. If however the gates move too quickly for
a particular installation, the voltage can be reduced to make the motors run slower.
NOTE:
Altering these
parameters will cause the travel limits to be cleared.
Parameter
Min
Max
Default
Step
Unit
Menu No.
OPEN SPEED VOLTAGE
Sets the full motor speed voltage in open
direction
12.0
24
22
1
Volts
6.1
CLOSE SPEED VOLTAGE
Sets the full motor speed voltage in close
direction
12.0
24
22
1
Volts
6.2
SLOW SPEED
Sets the motor speed voltage in soft stop cycle
6
24
8
1
Volts
6.3
SLOW TIME
Sets the time for soft stop cycle
0.1
10.0
3.0
0.1
Sec
6.4
HOMING SPEED
Sets the motor speed for fi rst cycle after power
failure
12
24
12
1
Volts
6.5