Owner Installation Instructions
GDO-11v1 Ero®
29
Default Settings & Specifi cations
Factory default settings
Default
Step
Maximum
Maximum motor run time
60 Secs.
-
-
Courtesy light time
3 Mins.
10 Sec in battery back
up mode
Obstruction force margin
0.5 Amp
0.1
2 Amp
Technical specifi cations
Power supply
230V - 240V AC 50Hz
Transformer rating
72 VA
Standby power
2.2 Watts
Motor power
90 Watts
Motor type
24V DC permanent magnet
Shuttle travel distance in the C-Rail
2.8m approx (standard)
Maximum shuttle travel distance in the C-Rail
4m (with extended C-Rail)
Maximum door opening:
Width:
(With 2775mm Standard track)
Height:
Weight:
5500mm (12m
2
)
2150mm
100 kg
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
Short term peak force
650N (65kg)
Lift force
400N (40kg)
Nominal force
150N (15kg)
Receiver type
Multi-frequency FM Receiver
Receiver code storage capacity
8 x 4 button transmitter codes
Transmitter frequency
433.47, 433.92, 434.37 MHz
Coding type
TrioCode™
Number of code combinations
Over 4.29 billion random codes
Code generation
Non-linear encryption algorithm
Transmitter battery
CR 2032
Courtesy light
Festoon style lamp 24 volts 15 watts
Controller fuse
10A slow blow
NOTE:
Intermittent operations may occur in areas which experience very strong winds. The strong wind
puts extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system
intermittently.
PE Beams should be fi tted as added safety in case of entrapment.