SL 90X-91X
Technical Manual
NAM-SL 90X-91X-TM-04-EN-E
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time
.
p. 48/66
10.7.
INSTRUCTIONS: REPLACING A FIXED GLASS OBSTACLE
1.
Locate the fixed glass obstacle mounting bolts [6] (see
) on the bracket (visible through
the moving obstacle when it is retracted into the unit).
2.
Remove the panel on the side of these mounting bolts (see
Section 10.1.
3.
Pull the moving glass obstacle in closed position.
4.
Lock the crankshaft using a shim (see
5.
Loosen the mounting bolts [6] without removing them (there are 4 or 5 mounting bolts, depending
on the width of the fixed glass obstacle).
6.
Pull the fixed glass obstacle upwards and remove it.
7.
Fit the new fixed glass obstacle in its bracket and tighten the mounting bolts [6].
Figure 30 Fixed obstacle mounting bolts