SL 90X-91X
Technical Manual
NAM-SL 90X-91X-TM-04-EN-E
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time
.
p. 34/66
9.7.
INDUCTIVE POSITION SENSOR
See item [3] on
Be careful not to move the sensor.
Make sure the sensor [3] and its bracket are well fastened.
Verify the cable and electrical connections.
Please refer to
Section 10.10.
for adjustment and calibration of the inductive position sensor.
9.8.
RODS AND ROCKERS
Figure 15 Rods and rockers
Verify that bolts are tight and that no parts are loose between the rods [2] and the rockers [1].
Look for premature damage, and plastic and metal grindings.
Grease moving parts, bushings and bearings.
1
2