Technical Instructions

UNI/59

Using the UNI/59 2
Specifications 2
Mounting 3
Power Wiring 3
Communicating with the UNI/59 3

Connecting to T-Line or U-Line modules 4
Connecting the UNI/59 to the CMnet 5

Addressing 5
Transferring Memory 6
Using Flow Sensors 6

Setting the flow sensor’s zero point (T-Line modules) 7

Troubleshooting 7

Understanding the Diagnostic Capture 7
Troubleshooting Tips 7
Communicating with the Workstation 8
Formatting the Module 9
LEDs 9
Protection 10
Production Date 10

Summary of Contents for UNI/59

Page 1: ...r brand and product names are trademarked by their respective companies Technical Instructions UNI 59 Using the UNI 59 2 Specifications 2 Mounting 3 Power Wiring 3 Communicating with the UNI 59 3 Conn...

Page 2: ...document at http www automatedlogic com or the SupportPlus CD for more information Make sure you use the correct module driver for your application CAUTION Changes or modifications to this unit not ex...

Page 3: ...100VA maximum Take appropriate isolation measures when mounting the UNI 59 module in a control panel where non Class 2 devices 120VAC or greater or wiring are present You can power several modules fr...

Page 4: ...modules The UNI 59 supports up to 59 T Line or U Line modules If you are using T Line modules you must use a REPOPT repeater after every 20 modules on the Unet If you are using U Line modules you must...

Page 5: ...To set the baud rate at 156 kbps when using an ARC156 CMnet set the baud rate jumper to Arc156 see Figure 5 To set the baud rate at 38 4 kbps set the baud rate jumper to 9600 38 4K and set the first...

Page 6: ...e UNI 59 s module driver and look at the module status report in SuperVision to make sure the module type and number agree with the module The module type for the UNI 59 is 76 To view the module statu...

Page 7: ...ur own cable use the diagrams in Figure 8 3 Set up your communications program with the correct COM port and baud rate settings to display the diagnostic information output by the UNI 59 The diagnosti...

Page 8: ...tch s position turn the UNI 59 module off first Once you have adjusted the switch turn the module back on 1 Connect the computer s serial port to the EIA 232 port of the APT using a standard straight...

Page 9: ...ains the Run and Error LED signals in detail to assist troubleshooting Power indicates power is being supplied to the module CMnet Tx lights when the module transmits data over the CMnet CMnet Rx ligh...

Page 10: ...ticker on the back of the module also shows the date the module was manufactured The first three characters on the sticker indicate the type of module The next two characters show the year and month o...

Reviews: