.06.
15
KW
Propane Gas Heater
PH
15
KW
Application use:
1.
Check the heater for possible shipping damage.
2.
Connect the hose and regulator assembly to the LPG cylinder by
rotating the nut counterclockwise into the LPG cylinder’s valve outlet and
securely tighten.
3.
Open the cylinder’s gas valve and check all gas connections with
a soap and water solution.
4.
Connect power cord to well-grounded 220-240V~, 50Hz source
of power.
3.1 IGNITION / Manual ignition
a.
Turn the power switch to position I and check that the fan starts
running correctly. (Fig 2.)
b.
Push the gas valve button and push repeatedly the piezoelectric
lighter until the flame lights up. (Figure. 3-4)
c.
As the flame lights up, keep the valve button pushed for 10 seconds
approx. Should the heater stop when the valve button has been released,
wait one minute and repeat the starting operation keeping the valve button
pushed for a longer time.
d.
Regulate the gas flow pressure according to the thermal power
desired, by turning the wheel of the pressure reducer anticlockwise to
increase the pressure or clockwise to decrease.
e.
Contact your supplier should any problem
s