background image

 

 

 

 

 

 

iMIG200DP

 

 

WARNING, please read all safety 
warnings and instructions. 

Failure to follow the warnings and instructions 
may result in electric shock, fire and/or serious 
injury. 
 

Save all warnings and instructions for 
future reference. 

The term “Power tool” in the warnings refers to 
your electric (corded) power tool or battery-
operated (cordless) power tool. 
 

1. Work area safety 

a) Keep work area clean and well lit. 

Cluttered or dark areas invite accidents. 

b) Do not operate power tools in explosive 
atmospheres, such as in the presence of 
flammable liquids, gases or dust. 

Power tools 

create sparks which may ignire the dust or 
fumes.

 

c) Keep children and bystanders away while 
operating a power tool.  

Distractions can cause 

you to lose control.

 

 

2. Electrical safety 

a) Power tool plugs must match the outlet. 
Never modify the plug in any way. 
Do not use any adaptor plugs with grounded 
power tools. 

Unmodified plugs and matching 

outlets will reduce risk of electric shock.

 

b} Avoid body contact with grounded surfaces, 
such as pipes, radiators, ranges and 
refridgerators. 

There is an increased risk of 

electric shock if your body is grounded.

 

c) Do not expose power tools to rain or wet 
conditions.

 Water entering a power tool will 

increase the risk of electric shock. 
 

GENERAL POWER TOOL SAFETY WARNINGS 

 

d) Do not abuse the cord. Never use the cord for 
carrying, pulling or unplugging the power tool. 
Keep cord away from heat, oil, sharp edges or 
moving parts. 

Damaged or entangled cords 

increase the risk of electric shock.

 

e) When operating a power tool outdoors, use an 
extension cord suitable for outdoor use. 

Use of a 

cord suitable for outdoor use reduces the risk of 
electric shock.

 

f) If operating a power tool in a damp location is 
unavoidable, use a residual current device (RCD) 
protected supply. 

Use of an RCD reduces the risk 

of electric shock.

 

 

3. Personal safety 

a) Stay alert, watch what you are doing and use 
common sense when operating a power tool. Do 
not use a power tool while you are tired or under 
the influence of drugs, alcohol or medication. 

moment of inattention while operating power 
tools may result in serious personal injury.

 

b) Use personal protective equipment. Always 
wear eye protection. 

Protective equipment such 

as dust mask, non-skid safety shoes, hard hat, or 
hearing protection used for appropriate conditions 
will reduce personal injuries. 

c) Prevent unintentional starting. Ensure the 
switch is in the off position before connecting to 
power source and/or battery pack, picking up or 
carrying the tool. 

Carrying power tools with your 

finger on the switch or energizing power tools that 
have the switch on invites accidents.

 

d) Remove any adjusting key or wrench before 
turning the power tool on. 

A wrench or a key left 

attached to a rotating part of the power tool may 
result in personal injury.

 

 

Summary of Contents for iMIG200DP

Page 1: ...SAFETY AND OPERATING MANUAL Dual Pulse MIG Welder iMIG200DP ORIGINAL INSTRUCTIONS...

Page 2: ...information necessary for using the product safely and to ensure its long service life Closely observe all safety information in these instructions General Power Tool Safety Warnings 3 Symbol Chart 8...

Page 3: ...se the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock...

Page 4: ...tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrainedusers GEN...

Page 5: ...ootwear Your shoes should also protect you in wet conditions Open toed footwear is not suitable since falling droplets of glowing metal will cause burns g Wear suitable clothing do not wear synthetic...

Page 6: ...The fuses on the supply cables to the mains sockets must comply with the relevant regulations VDE 0100 To comply with these regulations only fuses or circuit breakers suitable for the cross section o...

Page 7: ...hat personnel in the vicinity are protected Unauthorized persons are to be kept away from the welding work b The walls in the immediate vicinity of stationary workplaces should not have a light color...

Page 8: ...8 iMIG200DP SYMBOL CHART...

Page 9: ...170 A Rated Duty Cycle 60 Steel Wire Diameter 0 8 1 0 mm Al Si Al Mg Wire Diameter 1 0 1 2 mm Efficiency 85 Insulation Class H Enclosure Protection IP21S Cooling Type Fan Weight 14 4KG Dimensions 535...

Page 10: ...ed will depend on your workpiece but you will need the corresponding roller and tips for the wire size fitted e g a 1mm roller lining and tips will be used with 1mm wire To fit the wire you put the wi...

Page 11: ...alloy you will need to use Al Si or Al Mg When welding with stainless or carbon steel you will need Fe Crni When using these wire types different liners will be needed For aluminum a plastic liner wil...

Page 12: ...replaced regularly Keep the welder in a dry place when not in use Check that the earth clamp can clamp sufficiently replace if necessary Make sure all cables are in good condition with no nicks or deg...

Page 13: ...motor not working Potentiometer knob broken Replace potentiometer knob Nozzle blocked Change nozzle Rollers too loose Tighten rollers 4 No pilot arc Earth cable faulty Change earth cable Earth clamped...

Page 14: ...ed Dealer you return the product at your own cost to Autojack s or the supplying Authorised Dealer s Premises For the examination to take place clearly stating the Returns Material Authorisation Numbe...

Page 15: ...respondence Failure to provide a Returns Material Authorisation Number may result in item being refused delivery 2 2 Any issues with the product resulting in a potential claim under the guarantee must...

Page 16: ...iness interruption or loss of business opportunity 3 2 This guarantee does not confer any rights other than these expressly set out avoice and does not cover any claims for consequential loss or damag...

Page 17: ...hat the iMIG200DP Welder is in compliance with the regulations included in theDirectives 2006 42 EC EC DECLARATION OF CONFORMITY Certificate for EC type examination delivered by AV Technology Ltd Unit...

Page 18: ...Negative Socket 2 Home Button 10 Power Cord 3 Current Adjustment Knob 11 Power Switch 4 Inductance Control Knob 12 Cooling Fan 5 Voltage Adjustment Knob MIG only 6 Euro Torch Connection 7 Positive So...

Page 19: ...19 iMIG200DP The following tables are for reference only For I shaped butt welding For flat head T shaped welding Welding Spec Tables...

Page 20: ...20 iMIG200DP For flat angle weld joints thin plates Welding Spec Tables...