Manufacturer
Maintenance Manual
AutoGyro
MTOsport
MMM-CV-E_16-06-13
Part E - 08-20-00 2-1
Page 1 of 2
08-20-00 2-1 LEVELING OF THE GYROPLANE
LNE
GENERAL, REFERENCES AND REQUIREMENTS
Task may only be performed by an organization or individual trained and entitled to do 'Line Maintenance'!
Secure gyroplane against unauthorized or unintended operation!
Gyroplane must be placed on level ground and restrained (blocks, chocks)
SPECIAL TOOLS AND CONSUMABLE MATERIALS
None
PRECAUTIONS AND SAFETY MEASURES
PROCEDURES
Measure Dimension D1
1
Use a tape measure and measure distance between mast reference point and fuselage reference point. See
Fig. 1 for reference.
NOTE:
Mast reference point is defined as the inner edge of the upper mast end.
Fuselage reference point is defined as the outer top edge of the ball joint.
2
Contact AutoGyro for reference values.