Autoglide CASA-50P User Manual Download Page 3

INSTRUCTIONS CASA-50P 

 

Page 3

 

                                 SLIDING GATE OPENER 

 

 

Warnings

 

 

 

Please  read  this  instruction  manual  carefully  before  the  installation  of  gate-automated 
system.

 

 

This  manual  is  exclusively  for  qualified  installation  personnel. 

Autoglide

  is  not 

responsible  for  improper  installation  and  failure  to  comply  with  local  electrical  and 
building regulations.

 

   Keep  all  the  components  of  CASA-50P  system  and  this manual for further            
   consultation 

 

Be  aware  of  the  hazards  that  may  exist  in  the  procedures  of  installation 
and  operation  of  the  gate-automated  system.  Besides,  the  installation 
must  be  carried  out  in conformity with local standards and regulations                                                         

 

If the system is correctly installed and used following all the standards and 
regulations, it will ensure a high degree of safety

 

 

Make  sure  that  the  gates  works  properly  before  installing  the  gate-
automated  system  and  confirm  the  gates  are  appropriate  for  the 
application.

 

 

Do    not    let    children    operate    or    play    with    the gate-automated 
system.

 

 

Do not cross the path of the gate-automated system when operating.

 

 

Please  keep  all  the  control  devices  and  any  other  pulse  generator  away 
from  children  to  avoid  the  gate-automated  system  being  activated 
accidentally.

 

 

Do  not  make  any  modifications  to  any  components  except  that  it  is 
mentioned in this manual.

 

 

Do not try to manually open or close the gates before you release the gear 
motor.

 

 

If  there  is  a  failure  that  cannot  be  solved  and  is  not  mentioned  in  this 
manual, please contact qualified installation personnel.

 

 

Do  not  use  the  gate-automated  system  before  all  the  procedures  and 
instructions have been carried out and thoroughly read.

 

 

Test  the  gate-automated  system  weekly  and  have  qualified  installation 
personnel to check and maintain the system at least every 6-month.

 

 

Install  warning  signs  (if  necessary)  on  the both  sides  of  the  gate  to  warn 
the people in the area of potential hazards.                                                                                                        

 

Summary of Contents for CASA-50P

Page 1: ...INSTRUCTIONS CASA 50P Page 1 SLIDING GATE OPENER ...

Page 2: ...p and Function Setting 3 1 Wire Connection 3 2 Transmitter Memorization and Erasing Process 3 3 System Learning Reset Process and LED Display 3 4 Programmable Function Setting 3 5 Testing and Checking 3 6 Recognition of LED 4 Technical Characteristics 4 1 Technical Data Sheet of Series 4 2 Photocell Data Sheet 4 3 Transmitter Data Sheet 4 4 Flashing Light Data Sheet 4 5 External Receiver Box Data ...

Page 3: ...e automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accidentally Do not make any modifications to any comp...

Page 4: ...allation Demonstration 1 24V DC sliding motor 2 Transmitter 3 Safety photo sensor 4 Flashing light 2 2 Description of Device a Operation gear b Limit switch device c 24Vdc motor d Back up batteries Optional e Release device f Control panel g Terminals of devices h Green Box Optional ...

Page 5: ...INSTRUCTIONS CASA 50P Page 5 SLIDING GATE OPENER 2 3 Dimension of Device 2 4 Installation of Gear Motor and Gear Rack ...

Page 6: ...ove rightward Step2 Insert the key and turn counterclockwise to unlock the device Step3 Turn counter clockwise of the bar to release the motor To restore the automation simply reverse the above procedure 3 Setup and Function Setting 3 1 Wire Connection If the LED display is in normal performing refer to 4 2 1 you can control the gate by either transmitters or the button On the board UP clockwise m...

Page 7: ...INSTRUCTIONS CASA 50P Page 7 SLIDING GATE OPENER Push Button 10 11 ...

Page 8: ...ory Press RF Learn button for 5 6 seconds as right LED display is on then wait for LED display off 3 3 System Learning Reset Process and LED Display CAUTION Before proceeding to system learning the transmitter memorizing process has to be completed 1 To Complete the System Learning Step1 Press SET then press SET DOWN for 3 seconds and the LED display shows LE 1 2 3 Step2 Press left button A on tim...

Page 9: ...tting is1 1 1 1 Counter clockwise Opening 2 Automatic closing 2 0 No automatic closing 1 This function can cause the gate to close automatically after the paused time 2 The factory setting is 2 2 15 seconds as the pause time 2 1 5 seconds 2 2 15 seconds 2 3 30 seconds 2 4 45 seconds 2 5 60 seconds 2 6 80 seconds 2 7 120 seconds 2 8 180 seconds 3 There actions of the photocells safety edge loop det...

Page 10: ...speed 6 1 80 The factory setting is 6 4 6 2 60 6 3 40 6 4 25 6 5 10 7 Over current settings 7 1 2A 1 The function can adjust the running force of motor to be compatible with the gate weight 2 The factory setting is 7 5 7 2 3A 7 3 4A 7 4 5A 7 5 6A 7 6 7A 7 7 8A 7 8 10A 8 Open partially pedestrian mode 8 1 3 seconds 1 The function can adjust the time of opening partially 2 The factory settings is 8 ...

Page 11: ...ting is C 1 C 2 B key C 3 C key C 4 D key E Open partially function key E 0 No function in transmitter The factory setting is E 2 E 1 A key E 2 B key E 3 C key E 4 D key F External device control function key F 0 No function in transmitter The factory setting is F 2 F 1 A key F 2 B key F 3 C key F 4 D key H Photocell 1 function H 0 Close The factory setting is H 0 H 1 Open J Photocell 2 function J...

Page 12: ...opening Logic F3 2 The reactions of the safety edge photocell when detecting obstacles Gate Status Safety Edge Photocell 1 Closed Stop opening No effect Open Reloads automatic closing time Stop during moving Stop opening closing Reloads automatic closing time Closing Reverses to open for 2 seconds Open Opening Reverses to close for 2 seconds No effect Logic F3 3 The reactions of the loop detector ...

Page 13: ...ntrol unit recognizes each device 3 6 Recognition of LED LED Indication Descriptions LED1 Photocells LED1 will be on when the first pair of the photocells are activated LED2 Photocells LED2 will be on when the second pair of the photocells are activated 4 Technical Characteristics MOTOR PL500E Gear type Worm Gear Peak thrust 5500N Nominal thrust 5000N Engine RPM 3800RPM Absorbed Power 144W Power s...

Page 14: ...Data Sheet Application Radio transmitter Frequency 433 92Mhz Coding Rolling code Buttons 2 for single gate or dual gate operation Power Supply 3V with one CR2032 button type lithium battery Operating Temperature 20 50 Dimension 71 5mm 33mm 14mm 4 3 Flashing Light Data Sheet Application For outdoor use Installation Wall mounted vertically Operating Temperature 20 50 Dimension 85mm 60 5mm 40 5mm 5 P...

Page 15: ...th the terminals Ph and GND on the P600B PCB RX Connect terminals 1 2 and 4 on the receiver with the terminals Ph GND and Ph1 on the P600B PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge Proprietary Intellectual Property Do not Distribute without authorization All rights Reserved Copyright 2015 Autoglide www autoglideglobal com ...

Reviews: