3.5 Testing and checking
Make sure the notices included in 1.1 General safety precaution “WARNINGS” has been carefully
observed.
1. Release the gear motor with the proper release key.
2.
Make sure the gate can be moved manually during opening and closing phases with a force of
max 390N (40 kg approx.)
3
. Lock the gear motor.
4
. Using the Key selector switch, push button device or the radio transmitter, test the opening, closing
and
stopping of the gate and make sure that the gate is in the intended direction.
5. Check the devices one by one (photocells, flashing light, key selector, etc.) and confirm the control
unit
recognizes each device.
3.6 Recognition of LED
LED Indication
Descriptions
LED1 Photocells
LED1 will be on when the first pair of the photocells are activated.
LED2 Photocells
LED2 will be on when the second pair of the photocells are activated.
4. Technical Characteristics
MOTOR
PL500E
Gear type
Worm Gear
Peak thrust
5500N
Nominal thrust
5000N
Engine RPM
3800RPM
Absorbed Power
144W
Power supply
24 Vdc
Nominal input power
6A
Maximum gate weight
Up to 500 KG
Maximum gate length
6M
Maximum operating current
5.5A for Maximum 10 secs
Operating Temperature
-20oC~+50oC
Dimension L x W x H mm.
250*170*275mm
Weight
8kg
Speed
27.10 cm/s
4.1 Photocell Data Sheet
Detection type
Through beam
Operating distance
25 meters
Response time
100ms
Input voltage
AC/DC 12~24V
Operating Temperature
-20
℃
~+60
℃
Protection class
IP54
Dimension
96mm * 45mm * 43mm