SINGLE OPERATING MANUAL
17
Failure to comply with this requirement may lead to voltage supply to the Charging Station
case, electric shock to service personnel and consumers, as well as to the Charging Station
failure.
ATTENTION!
When connecting the Charging Station to the mains, it is necessary to use a separate circuit
breaker, the power and number of phases of which is calculated depending on the
configuration of the Charging Station.
For the Charging Station with a J1772 connector and a capacity of 9.2kW, it is recommended to
use a single-phase circuit breaker with a breaking current of 50A.
For the Charging Station with a Type 2 connector (Menekes) with a capacity of 22kW, it is
recommended to use a three-phase circuit breaker with a breaking current of 40A.
Further, with the external switching devices, it is necessary to connect the power cable to the
AC network and then to turn the three-pole circuit breakers into the operating position.
In order to turn on the Charging Station, it is necessary to:
•
Install the SIM card (if a modem is installed in the Charging Station)) of the mobile network
operator (if an external SIM card is used). To do this, please follow these steps:
-
remove the ChS cover by unscrewing two screws on the back of the Station;
-
remove the modem cover;
-
install a SIM card;
-
close the modem cover;
-
put on the ChS cover by screwing in two screws on the back of the Station;
•
Move the circuit breaker on the switchboard to the operating position (up).
5 INTENDED USE
5.1 OPERATING MODES AND ELECTRIC VEHICLE CHARGING
Information about the ChS operating modes (the state of the connectors and the charging
parameters) is shown on the display. The display also shows data on software versions, a modem
number, the Station number in Autoenterprise billing, a mobile network status, etc.
The information shown on the display depends on the software version and may differ from
version to version.
After the supply voltage is applied, the Station display
shows information about the software version and the
modem serial number.
In the event of a malfunction of the Charging Station, you
should inform the serial number of the modem to the
service center for diagnostics and restoration of its work.