background image

INSTRUCTION MANUAL CHARGE COMPLEX «K»

6

2.4    DISPOSAL INFORMATION

Do not dispose of the charging complex together with household 

waste!

Electronic devices must be disposed of in accordance with the local 

directives for the disposal of electronic and electrical waste. If you have 

any further questions, please contact your supplier.

Use suitable tools if you need to disassemble the system. All individual parts must be sorted 

by different types of material and disposed of in accordance with the regional guidelines for 

the disposal of electronic and electrical waste.

2.5    MANUFACTURER’S LABEL

The marking on the charging complex is located on the GSM modem inside the complex on 

the side of the control panel (side 1) and consists of alphabetic and digital symbols (example: 

M123456).

This information is important for setting up, troubleshooting and ordering 

spare parts for the station.

ERM4-012

DCL

A2

A1

EVCC-DC-003

EVCC-АC-003

EVCC-GSM

        002

MW

MDR

40-12

L

N

+V+V -V -V

MW

MDR

40-12

L

N

+V+V -V -V

MW

MDR

40-12

L

N

+V+V -V -V

MW

MDR

40-12

L

N

+V+V -V -V

MW

HDR

30-12

V+

V-

N

L

on

ETI EFI6-4 40/0,03-AC 

on

ETI C6

on

ETI C25

on

ETI

on

ETI

EFI6-2 63/003-AC

монтажная компоновка зарядного комплекса - сторона 1

A1

A2

ETI

RA40-40

fA1

A22

ETI

R63-20

монтажная компоновка «Мультистанция» сторона 2

-

    

+

DGR 150

LEM HO 150 S

EVR150-12S

ETI 6 3P C32

on

on

on

ETI 6 3P C32

on

on

on

ETI 6 3P C32

on

on

on

ETI 6 3P C32

on

on

on

DGR 150

DGR 150

DGR 150

(Вер. 1_1        27.05.2019)

EVR150-12S

DGR 150

DGR 150

М123456

Серийный номер

зарядного комплекса 

SERIAL NUMBER

Summary of Contents for CHARGE COMPLEX K Series

Page 1: ...CHARGE COMPLEX K Instruction manual...

Page 2: ...written permission Any violation of the law will be prosecuted Autoenterprise cannot be held liable for any direct or indirect damages resulting from the use or operation of the electrical circuits o...

Page 3: ...abel 6 3 Application area station specifications 7 3 1 Application area 7 3 2 Complex Specifications 7 3 3 Equipment modifications 9 3 4 General electrical safety information 9 4 Technical specificati...

Page 4: ...t allow for the exchange of information with the electric vehicle and set the value of the charge current and voltage according to the needs of the electric vehicle in real time 2 KEY INFORMATION 2 1...

Page 5: ...y subsequent damages or consequential damages Strict adherence to the safety procedures described in these operating instructions and special care when using the equipment are essential to prevent and...

Page 6: ...onal guidelines for the disposal of electronic and electrical waste 2 5 MANUFACTURER S LABEL The marking on the charging complex is located on the GSM modem inside the complex on the side of the contr...

Page 7: ...ended use Only charge compatible electric vehicles Failure to follow the instructions for use maintenance and repair described in these operating instructions excludes any liability on the part of the...

Page 8: ...ptional Stand alone operation Delivery contents Charging station user manual Charging station dimensions 314 1056 2122 mm Type of installation Floor Wall mounting Online device monitoring Yes Current...

Page 9: ...3 4 GENERAL ELECTRICAL SAFETY INFORMATION Follow the safety instructions to avoid injury and material damage when working with the device Failure to follow these instructions can result in injury and...

Page 10: ...tation is structurally designed as a monoblock mounted on a pillar and has the following control and management bodies Encased charging station on a pillar 1 pc Connector Type 1 with cable 1 pc Connec...

Page 11: ...2 Mennekes 1 3 63 43 380 CHAdeMO 1 125 60 480 CCS Type 2 1 125 60 480 CHARGE COMPLEX K 2 Socket type Quantity Current Max power kWh Max voltage V Type 1 SAE J1772 1 80 19 240 Type 2 Mennekes 1 3 63 4...

Page 12: ...The emergency stop button is located at the bottom of the unit housing When the emergency stop button is pressed in DC charging mode the charging station control circuit is automatically deactivated...

Page 13: ...t the charging complex with the utmost care Take into account the centre of gravity of the charging system during transportation minimize the risk of tipping over Take measures to prevent the charger...

Page 14: ...wer cable not included in the delivery set When routing the power cable appropriate insulation must be used It is recommended to lay and connect the power cable inside the charging station s rack befo...

Page 15: ...it is necessary to connect the power cable to the AC mains and then move the three pole circuit breakers 1 2 3 and 4 to the working position up The operating modes of the charging complex are displaye...

Page 16: ...the service center about the factory number of the charging complex the number of the charging complex is shown in the pic M006335 While the vehicle charging mode is active station displays informati...

Page 17: ...ld be dry free of dust caustic materials vapours and combustible materials Storeinastorageroomwithappropriateweatherprotection Do not expose the charger to impacts Storageconditions Storage Temperatur...

Page 18: ...tem operation and strictly adhere to all safety instructions In the course of operation the following maintenance are carried out Visual inspection for overheating of equipment check pulling connectio...

Page 19: ...find out the reason for the lack of voltage Circuit breakers or RCD charging system triggered Restore the operation circuit breakers or RCDs of the charging complex Other malfunctions The charging com...

Page 20: ...supply by means of external disconnection devices IN SEQUENCE 1 Make sure that the input voltage of the charger is disconnected 2 Carry out disassembly work INFORMATION Always use suitable tools to d...

Reviews: