Code
Error
Action
Message
C3 Platter Ref
mark not
detected.
Check the wind count and Attempt to
recalibrate 3 times with no error. If
unsuccessful throw error and lock touch
screen.
“Ref Tab not detected on
platter X see supervisor”
Notes: When a C3 error occurs the affected platter did not detect the magnetic indicator on the platter
(MP) or the chain. This can be caused by damage to the indicator or the magnetic pickup. If this happens
the controller can no longer store its wind count to volatile memory. This could cause a severe wind up
problem. The C3 error stops this from happening. If this occurs one should check the ref mark indicator
lights on the controller (red led) The MP led should light when the Ref tab passes the magnetic pickup.
On all other platters the indicator light should stay on until the Ref tab passes magnetic or optical pickup.
If this does not occur the machine may have wiring problem or a bad controller.
C
Code
Error
Action
Message
C4 Platter Ref
mark was
detected but
not with the
Ref error
limitation.
Check wind count and Attempt to
recalibrate 3 times with no error. If
unsuccessful throw error and lock touch
screen.
“Ref Tab not detected on
platter X see supervisor”
Notes: A C4 error is caused by a condition where the machine has rotated more than 84 pulses past where
it expected to see the Ref mark on the affected platter. This can be caused by a missing Ref tab or more
likely the use of the manual platter movement switches. If a user moves the platter in a direction that
would move it pass the ref tab and then the machine fetches a bin in the opposite direction that condition
could occur where the machine would detect more than the limiting pulses. The machine will normally
self correct this condition by recalibrating.
C
Code
Error
Action
Message
C5 Baffle pot
voltage out of
range.
None then lock the touch screen. The
administrator must use manual switch to
move to position 1 check the rack and
pinion and then perform a “CPR B”
Command from the maintain screen.
“Baffle over traveled See
supervisor”
Notes: A C5 error normally occurs when the baffle motor overdrives the pinion on the rack. Once this
happens the user must check the rack and pinion to see if any damage has occurred. If the pinion is still
engaged on the rack the system administrator should use the manual baffle switch to position 1 or the 12
th
pie configuration setting. Next the administrator should use the Maintain screen on the touch screen to
reset the baffle pot voltage. The command used to do this is “CPR B” once this has been completed the
machine should be restarted to force a calibration.
26