Autocall A59AO-APPLWR Installation Instructions Download Page 4

579-1200AC  Rev. D

© 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall
product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National
Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA).

Appliance specifications

Table 2: Environmental specifications

Specification

Rating

Rated voltage range SPECIAL APPLICATION 23-29.5 VRMS
Temperature range 32 °F to 120 °F (0 °C to 49 °C)
Humidity range

10% to 93%, non-condensing at 104 °F (40 °C)

Connections

Terminal for 18 AWG to 12 AWG
(0.82 mm

2

 to 3.31 mm

2

)

Table 3: Sound pressure level measurement (dBA)

Reverberant room at ten feet in accordance with

UL464 (See note 2)

Voltage (Vrms)

Horn Mode Steady

Horn Mode Coded (See Note 1)

23

86.9

83.3

High Volume Setting using Addressable Controller

(See Note 3)

29.5

88.4

84.7

23

85.7

81.2

Low Volume Setting using Addressable Controller

(See Note 3)

29.5

87.7

83.3

Anechoic room at 10 feet in accordance with ULC

S525, see note 4.

see note 4

23

93.8

93.7

High Volume Setting

29.5

95.2

95.1

23

87.5

87.4

Low Volume Setting

29.5

89.5

89.4

Note:

1.

The coded category covers both Temporal and March time cadences.

2.

Reverberant

 dBA measurements are a minimum UL rating based on sound power level measurements made in UL’s reverberant test

chamber.

3.

High and low volume settings are configured with DIP Switch (CFIG1). See Figure 4.

4.

If you install the A4905-9838 Sound Damper, the anechoic measurements decrease by approximately 9 dBA.

Table 4: ULC directional characteristics for horn

Axis

Angle

dBA

50° left and right

-3dBA

Horizontal

63° left and right

-6dBA

20° above / 48° below

-3dBA

Vertical

65° above / 60° below

-6dBA

CAUTION:

• The appliances are available in red and white. Do not paint or otherwise alter the factory finishes in any way.
• Anechoic dBA levels below 85 do not meet ULC requirements for public notification.

Table 5: Maximum RMS operating current

Specification

Rating

Appliance Type

23V*

AO

27 mA

* For connection to IDNAC SLCs

Summary of Contents for A59AO-APPLWR

Page 1: ...Signaling Code NFPA 72 ULC Standard CAN ULC S524 Installation of Fire Alarm Systems the appropriate model building codes etc and specific requirements of the local Authority Having Jurisdiction AHJ These notification appliances are not intended for installation within hazardous locations as defined by the National Electrical Code NEC or NFPA UL listed TrueAlert ES indoor product identification ref...

Page 2: ...es on an IDNAC channel is 127 The maximum number of active appliances is limited to 3 amps per circuit Refer to the field wiring diagrams for the driving compatible fire alarm control panel for further instructions b Notification appliances are rated using an individual module label c Maintain the correct polarity on the terminal connections d Terminals and can each accommodate 2 wires one wire go...

Page 3: ... the switches using a non metallic stylus or the equivalent 3 Record the set address 4 Confirm the setting for the appliance at this address with the Fire Alarm Control Panel FACP system configuration documentation DIP switch position 8 determines whether this appliance is viewed by the system as an ALARM OFF or ALERT ON type appliance Figure 3 Setting the DIP switch address Setting the appliance ...

Page 4: ... Note 1 23 86 9 83 3 High Volume Setting using Addressable Controller See Note 3 29 5 88 4 84 7 23 85 7 81 2 Low Volume Setting using Addressable Controller See Note 3 29 5 87 7 83 3 Anechoic room at 10 feet in accordance with ULC S525 see note 4 see note 4 23 93 8 93 7 High Volume Setting 29 5 95 2 95 1 23 87 5 87 4 Low Volume Setting 29 5 89 5 89 4 Note 1 The coded category covers both Temporal ...

Reviews: