36
www.auto-trail.co.uk
Truma CP
This warning triangle symbol indicates that the
Combi heater is not currently running due to a
requirement of 240 volt Electric or 12volt supply
or it is in a cool down procedure.
Once 240 volts
is connected or
12volt supply is
switch on the Combi
will automatically
re start.
To Read out warning code
– Select the triangle icon with rotary push button.
– Tap the rotary push button.
The current warning code will be displayed.
The cause of the warning can be determined
and remedied with the aid of the troubleshooting
guide
W = Warning
42 = Fault code
H = Heater
Error Code
In the event of an Error occurring the Truma CP
plus control panel will immediately displays the
error code on the screen.
The cause of the Error can be determined and
remedied with the aid of the trouble-shooting
guide found at the back of the handbook.
Resetting Error code
– Once you have identified and solved the error.
i.e. ensuring a good supply of gas etc.
– You then need to tap the rotary button to
activate the background lighting and then
scroll to warning triangle and tap again to
acknowledge the Error.
– The Combi will restart at this point.
If you do not follow procedure and keep pressing
the incorrect icons the Cp+ plus will go into
safe mode. The fault code flashes in the control
panel display, this cannot be reset until up to 15
minutes have elapsed.
Warning
W 407 H
E 517 H