background image

 

April 10, 2019 (1.1) 

 

 

 

 

 

Publication P/N: 1100409  

 

 

 

 

 

 

 

 

 

 

Copyright © Auto-Maskin AS, 2019 

 

 

Specifications 

 

Installation Steps 

Configuration Steps

 

Measurements 

 

Section 

Width 

Height 

Depth 

Unit 

Size 

163 

131 

75 

mm 

 

Power Ratings 

 

Section 

Min 

Typ. 

Max 

Unit 

Power 
Supply, Vcc 

12/24 

0.5

 

32 

VDC 

 

Max ripple 10% without exceeding Min and Max values. 

 

 Connectors

 

 

 

USB 

 

 

RJ45, 
Ether-
net 

 

 

C1: 
Power 
CAN, 
RIO, 
IO1-4 

C2: 
Relay1, 

Relay2, 

AllFaults, 

IO5,20,21 

C3: 
IO6-17 

C4: 
MPU, 
RS-485, 
Therm1&2  
IO18,19 

 

 

 

1.

 

Remove the unit from the ESD Bag. 

2.

 

The unit comes with DIN-Rail mounting clips 
for easy snap clips on the rear side of the 
unit.     

3.

 

Attach the Power Supply connector (CON1) 
and make sure the power ratings are within 
product specifications. 

4.

 

Connect additional external connectors 
(CON2-4) according to specification related to 
the applicable application.  This may include 
the following: 
* CAN bus (J1939) 
* All Faults 
* Switch Inputs 
* Magnetic Pickup 
* PT 100 Sensors 
* 4-20 mA Sensors 
* RIO Link 

5.

 

For improved sealing use a RJ45 connector 
cap. 

 

A Connector Kit (P/N: 1006479) with four 
Deutsch DT-connectors, crimp sockets and 
sealing plugs is available. See the Installation 
Manual for further information. 

 

The DCU has a built in web server with access to 
a full configuration of the unit. 

 

PC Connection/Setup: 

 

Connect via Ethernet using a Net Browser 

 

From the Address Field in the Browser, type 
the IP-Address.  Factory Default is 

192.168.0.101.

 

 

Then log in to the unit.  Factory Default 

Username is ‘

DCU’

 and Factory Default 

password is ‘

1234’

 
For further details and information, please see 
the Configuration Manual. 

 

 

 

 

Responsibilites: 

It is the 

sole responsibility of the installer

 to ensure that the 

installation work is carried out in a satisfactorily manner and 
meet all applicable rules and regulations. 

 

Note: 

Auto-Maskin continuously upgrades its products and reserves 
the right to make changes and improvements without prior 
notice. 

Additional Documentation: 

Please visit the Marine Pro 200 section of the Auto-Maskin 
web site for the following enhanced documentation: 

 

Installation Manual 

 

Configuration Manual 

 

User’s Manual.

 

 

http://www.auto-maskin.com

 

 