1 Preface

1.1 About this Manual

This manual has been published primarily for professionals and qualified personnel.
The user of this material is assumed to have basic knowledge in marine systems, and must
be able to carry out related electrical work.

Work on the low-voltage circuit should only be carried out by qualified and
experienced personnel.
Installation or work on the shore power equipment must only be carried out by
electricians authorized to work with such installations.

1.2 Responsibilities

It is the sole responsibility of the installer to ensure that the installation work is
carried out in a satisfactory manner, that it is operationally in good order, that the
approved material and accessories are used and that the installation meets all
applicable rules and regulations.

Auto-Maskin continuously upgrades its products and reserves the right to make
changes and improvements without prior notice.

All information in this manual is based upon information at the time of printing. For updated
information, please contact your local distributor.

The crossed-out wheeled bin symbol indicates that the item should be
disposed of separately. The item should be handed in for recycling in
accordance with local environmental regulations for waste disposal.

By separating a marked item, you will help reduce the volume of waste
sent to incinerators or land-fill and minimize any potential negative impact
on human health and the environment.

1.3 Revisions

This User Manual is valid for the following firmware version of the SDU 404 and SDU 420.

Firmware Version

Release Date

1.4

Jan 2022

Page 3 (10)

Summary of Contents for 1006418

Page 1: ...Publication P N 1100520 User Manual 400 Series SDU 404 Safety Shutdown Unit P N 1006418 SDU 420 Safety Shutdown Unit P N 1500158...

Page 2: ...ction 6 4 2 Analog Channels 6 4 2 1 Sensor Fault Detection 6 4 3 Pickup Channel 6 5 Shutdown Situations 7 5 1 From Overspeed 7 5 1 1 Shutdown Override 7 5 1 2 Indication 7 5 1 3 Acknowledge 7 5 2 From...

Page 3: ...cessories are used and that the installation meets all applicable rules and regulations Auto Maskin continuously upgrades its products and reserves the right to make changes and improvements without p...

Page 4: ...uary 2022 2 Ordering Information The Marine Pro covers a wide range of compatible products within both the 200 and 400 Series Please visit our website for more information http auto maskin com marine...

Page 5: ...nfig Amber Flashing when unacknowledged fault Steady lit when acknowledged fault MPU Amber Flashing when unacknowledged fault Steady lit when acknowledged fault Green Steady lit when MPU connected ACK...

Page 6: ...e switch input terminals 4 1 2 Short CIrcuit Detection When correctly wired and configured see Installation Manual this will be detected and indicated at the LED next to the switch input terminals 4 2...

Page 7: ...analog channels indicate a shutdown then the SDU will activate the common shutdown outputs 5 2 1 Shutdown Override Each channel may be configured to disregard the Shutdown Override input command 5 2...

Page 8: ...00 rpm Deactivates when the SDU senses that the engine has stopped OVERSPEED SHUTDOWN Activates for any overspeed shutdown Deactivates when engine is stopped 5 RPM and a configurable delay and overspe...

Page 9: ...peed Shutdown at 95 of the Nominal setpoint Pressing the Overspeed Test button again Automatic timeout after 5 minutes 7 2 Shutdown Override Connect a normally open NO switch with a 10 k ohm resistor...

Page 10: ...y shutdown override Can be used to override shutdown individually per channel similar to the normal shutdown override Connect a normally open NO switch across the two terminal inputs SDU 404 16 and 17...