Wear safety glasses and protective clothing. 

 

NEVER smoke or allow a spark or flame in vicinity of battery or engine. 

 

Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. 

 

If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, 
immediately flush eye with cold running water for at least ten minutes and get medical attention 
immediately. 

 

Use caution when working with metallic tools to prevent sparks or short circuits.   

 

Remove any jewelry or watches before you start servicing the battery.   

 

Keep hair, hands, and clothing as well as tester leads and cords away from moving blades and 
belts. 

 

 

 

 

Summary of Contents for MaxiBAS B200

Page 1: ...rmation available at the time of printing Autel reserves the right to make changes at any time without notice While information of this manual has been carefully checked for accuracy no guarantee is given for the completeness and correctness of the contents including but not limited to the product specifications functions and illustrations Autel will not be liable for any direct special incidental...

Page 2: ... and applicable test procedures provided by the manufacturer of the vehicle or equipment being tested Use the device only as described in this manual Read understand and follow all safety messages and instructions in this manual Safety Messages Safety messages are provided to help prevent personal injury and equipment damage All safety messages are introduced by a signal word indicating the hazard...

Page 3: ...tacts skin or clothing wash immediately with soap and water If acid enters eye immediately flush eye with cold running water for at least ten minutes and get medical attention immediately Use caution when working with metallic tools to prevent sparks or short circuits Remove any jewelry or watches before you start servicing the battery Keep hair hands and clothing as well as tester leads and cords...

Page 4: ...tant Messages 1 Hyperlink 1 Illustrations 1 2 General Introduction 2 Function Description 2 Technical Specifications 3 3 Getting Started 5 Inspect the Battery 5 Power Up 5 Connect to a Battery 5 4 Service Procedures 7 Technical Support 7 Repair Service 8 Other Services 8 5 Compliance Information 9 6 Warranty 11 Limited One Year Warranty 11 ...

Page 5: ... to 5 charging and discharging cycles Important IMPORTANT indicates a situation which if not avoided may result in damage to the tablet or vehicle Example IMPORTANT Keep the cable away from heat oil sharp edges and moving parts Replace damaged cables immediately Hyperlink Hyperlinks or links that take you to other related articles procedures and illustrations are available in electronic documents ...

Page 6: ...an provide a quick health status check of the existing battery register a new battery and perform advanced battery and electrical system diagnostics The B200 can also connects to a multimeter to test voltage and current The B200 package includes a tester with a clamp cable a multimeter optional and a MaxiBAS app Function Description MaxiBAS B200 Tester 1 Power Button 2 Status LED 3 Power LED 4 USB...

Page 7: ...s Bluetooth Power 6V 36V Operating Temperature 10 to 50 Storage Temperature 20 to 60 Dimensions 107x75x26mm Net Weight 320g left current clamp Table 2 2 Technical Specifications of the Multimeter Item Description DC Voltage Range 200V AC Voltage Range RMS 200V Resistance Range 10 MΩ Current Range 0 to 65A 65A current clamp 0 to 650A 650A current clamp Diode 2V Continuity Test 70 Ω 6 7 8 ...

Page 8: ...is communicating via Bluetooth Flashing Red Battery clamps are connected to the wrong battery terminals Power LED Green Solid Green The tester is powered on and the battery is sufficiently charged Flashing Green The tester is charging turns to Solid Green after its battery is fully charged Red Flashing Red The tester s battery level is low please charge ...

Page 9: ...re of water and baking soda Wear protective glasses and gloves when working with batteries IMPORTANT Please ensure that the B200 is powered ON when pairing the device and during registration Power Up 1 Scan the QR code or search for MaxiBAS in App Store or Google Play Store to download and install the app to your device 2 Open the MaxiBAS app and follow on screen instructions to complete the regis...

Page 10: ...6 the battery ...

Page 11: ... Phone 0049 0 6103 2000520 Monday Friday 9 00AM 6 00PM Berlin Time Website www autel eu Email sales eu autel com support eu autel com Address Adalperostraße 82 85737 Ismaning Germany AUTEL CHINA HQ Phone 0086 755 2267 2493 Monday Friday 9 00AM 6 00PM Beijing Time Website www autel com Email support autel com Address 6th 10th floor Building B1 Zhiyuan Xueyuan Road Xili Nanshan Shenzhen 518055 China...

Page 12: ... information must be included Contact name Return address Telephone number Product name Complete description of the problem Proof of purchase for warranty repairs Preferred method of payment for non warranty repairs NOTE For non warranty repairs payment can be made with Visa Master Card or with approved credit terms Send the device to your local distributor or to the below address 6th 10th Floor B...

Page 13: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 14: ... declared to conform to the essential requirements of the following Directives and carries the CE mark accordingly EMC ETSIEN301489 1 V2 2 3 2019 11 ETSIEN301489 17 V3 1 1 2017 02 Safety EN62368 1 2014 A11 2017 Health EN50663 2017 EN62479 2010 Directive 2014 53 EU ...

Page 15: ...ve limitations may not apply to you This warranty does not apply to a Products subjected to abnormal use or conditions accident mishandling neglect unauthorized alteration misuse improper installation or repair or improper storage b Products whose mechanical serial number or electronic serial number has been removed altered or defaced c Damage from exposure to excessive temperatures or extreme env...

Reviews: