![AUTEC C26PRO SERIES User Manual Download Page 14](http://html.mh-extra.com/html/autec/c26pro-series/c26pro-series_user-manual_3020248014.webp)
- 10 -
LIPROMA3-00
- 10 Re
ceiving unit -
FLOW
Activating a movement command also activates the FLOW function: this commands
the solenoid valve which puts the oil in the hydraulic circuit of the main distributor
under pressure.
T.S.
T.S. (TIMED STOP) is the command that switches off the machine diesel motor: it re-
mains active for 10 seconds after the STOP pushbutton has been pressed.
Fuse
The three fuses inside the receiving unit have the following characteristics:
Fuse
Function
Technical Data
F1
POWER SUPPLY circuit protection
4A (32Vdc, autofuse)
F2
STOP circuit protection
10A (32Vdc, autofuse)
F3
SAFETY circuit protection
10A (32Vdc, autofuse)