Operating manual Fireplac inserts schieb flat + II
EN
5 | Technical data
37
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.2
General specifications
Model
65x S
75x S
75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
EN test EN 13229
CE mark
Nominal heat efficiency in [kW]
8
10
10
12
10
11
12
13
Maximum heat output [kW]
11
14
14
16
15
16
17
17
Max. length of logs
33
33
33
33
33
33
33
33
permissible fuel filling quantity [Kg]
2.35
3.2
3.2
3.4
3.2
3.4
3.4
3.5
Fuel throughput, maximum [kg/h]
2.3
2.85
2.85
3.5
2.13
2.56
2.56
3.97
Cross-section, convection outlet [cm²]
700
700
700
1820
1000
1200/
1000
1200/
1000
2940
Cross-section, convection inlet [cm²]
700
700
700
1170
1000
1000
1000
2320
Power output via pane [%]
17/
20/20
17/
23
29
34
29/
50
23/
28
23/
28
32
Emissions values
65x S
75x S
75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
CO [mg/Nm³]
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
Dust based on 13% O2
≤40
≤40
≤40
≤40
≤40
≤40
≤40
≤40
OGC [mg/MJ]
≤50
≤50
≤50
≤50
≤50
≤50
≤50
≤50
NOx based on 13% O2[mg/m³]
≤150
≤150
≤150
≤150
≤150
≤150
≤150
≤150
Efficiency [%]
≥80
≥80
≥80
≥80
≥80
≥80
≥80
≥80
Flue gas temperature [°C]
***)
283 /
298 /
317
313/300
286
252
312/291 274/288 274/288
254
Flue gas mass flow [g/s]
7.3 /
7.7 / 6.8
8.1/7.7
7.3
13.07
8.28/8.4
3
9.9
9.9
14.88
Minimum feed pressure at nominal
heat output [Pa]
12
12
12
13
12
12
12
13
Distances from fireplace insert
65x S
75x S
75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
Distances from fireplace insert to
heating chamber wall [cm]
6