© Austria Email AG
10
V1.0 1/2021
ATTENTION
Disposal must be performed in accordance with the local and national
provisions.
3.3.10
Directives
Disposal of the refrigerant must be carried out in accordance with Directive 842/2006/EC, as well as
other national and local regulations.
4
Technical Description
4.1
General
This device is a heat pump used for domestic hot water (DHW) heating in residential or small office
buildings where daily consumption of hot water does not exceed 500 litres (WPA 230 ECO) / 700 litres
(WPA 302 ECO). While heating tap water, the heat pump simultaneously cools down the area where it
is installed or from which the air is taken. In addition to tap water heating, the heat pump may also be
used to cool down a selected room (e.g. cellar, storage room, etc.), but it needs to be stressed, that
the cooling will only take place simultaneously with tap water heating. If there is no need for tap water
heating, the cooling will also not be carried out.
To achieve high efficiency and savings it is recommended to use air from rooms with waste heat (boiler
rooms, laundries, kitchens, basements, storage rooms, etc.) as a heat source.
Dimensions: