STANDBY ENERGY CONSUMPTION

If a water heater is heated up and no water is released for a long time after the heating process, a cooling 
of the stored water via the surface of the device, albeit gradual but continuous, will be the result.
The intensity and speed of his cooling off will vary according to the construction type of the device, the 
size of the device, thickness and quality of the container insulation.

This behaviour is measured at a stored water temperature of 65°C over a period of 24 hours and the 
amount of energy required to keep the water at a constant temperature throughout this period is meas-
ured in kWh.

Nominal capacity in litres

80

100

120

150

Standby energy consumption 
kWh/24h

0.95

1.08

1.23

1.45

OPERATING THE ECO CLEVER CONTROL SYSTEM (LCD VERSION)

Operation

The LCD controller has 3 push buttons which can be used to select the desired operating 
mode.

This button is used used to select between the 3 different operating modes.
Press the Mode button once or multiple times to select the desired mode – the desired func-
tion appears on the display.
By pressing and holding down this button for at least 3 seconds, the device can be switched 
on or off. 

Clever

This mode is used for saving energy effectively. The controller adjusts to the user’s behaviour 
and heats up the water only when it is needed.

Manual

In this mode the hot water temperature is constantly adjusted to the comfort level which is 
selected.

Holiday / Standby

In this mode the tank does not heat-up the water over a set period, unless the water temper-
ature falls below 7°C.

mode-selecting

operation mode

child lock

maintenance and error indicator

buttons to select

level of comfort and

holiday days

holiday days or

error code

Summary of Contents for eco clever 100

Page 1: ...Operating and Installation Instructions ECO CLEVER Please forward this on to the user Id no 242440 7 Pressure resistant electric water heater 80 100 120 150 Litres...

Page 2: ...gy consumption For the sake of the environment the ARA Junk Recycling Austria AG licence enables you to have the packaging of your device professionally disposed of The installation and initial commis...

Page 3: ...lay backlighting 9 Error codes 10 Troubleshooting 11 Control unit 12 Operating Requirements 13 Installation and Safety Information 13 Dimensions Sketch 15 Product Data ErP 16 Domestic Hot Water Side C...

Page 4: ...rface install supporting feet depending on the type Ensure that the subsurface at the installation location has a sufficient load bearing capacity The storage tank may only be set up in dry frost prot...

Page 5: ...ew standard values for consumption The temperature of the cold water required for mixing for the stated hot water temperature was assumed to be approx 12 C SAVING ENERGY Our electrical storage system...

Page 6: ...CONTROL SYSTEM LCD VERSION Operation The LCD controller has 3 push buttons which can be used to select the desired operating mode This button is used used to select between the 3 different operating m...

Page 7: ...mode after the set days have elapsed The level of comfort and the number of holiday days can be set using these buttons If the tank is correctly installed and filled completely with water the electric...

Page 8: ...g 1 2 3 recommended standard setting 4 5 Comfort level 3 complies with the requirements of prEN 15440 and corresponds to 80 of the possible hot water content 3 seconds after you have selected the leve...

Page 9: ...e monitors the tank temperature When unfa vourable conditions are detected a protection cycle is automatically started and the water is heated up to 65 C If the system is in holiday mode and a protect...

Page 10: ...ry operation There is no water in the tank 2 Unexpectedly long heating duration There are several possible causes Defective heating element Defective relay Uncontrolled water leakage Increased hot wat...

Page 11: ...de 6 Data connections Disconnect the tank from the power supply Check the data cables and replace if necessary Nothing appears on the display when power is ON Attention Only for specialists Check the...

Page 12: ...N Tank heating up Rapid flashing ON 1s OFF 1s Error detected Rapid double flashing upon starting 2x ON 0 5s 2x OFF 0 5s during power up Confirmation that the device is in the standard setting Reset af...

Page 13: ...take notice of this warning could result in personal injury due to a falling device b Every device is delivered with a wall rail for the insertion of the upper securing hook which is attached to the w...

Page 14: ...nce with good engineering practice We recommend the installation of insulating screw fixings h If there is particularly aggressive water which demands a special solution on the installation side the p...

Page 15: ...t in kg H A B B adjustable from to 80 Hanging storage tank 751 280 400 400 550 40 100 Hanging storage tank 884 280 600 400 700 46 120 Hanging storage tank 1019 280 600 550 850 52 150 Hanging storage t...

Page 16: ...SSURE RESISTANT In cases in which unsuitable or non functional storage tank connection fittings are used as well as in cas es in which the stated operating pressure is exceeded we shall refuse to guar...

Page 17: ...queued water is drained off completely via the funnel or outlet pipe b In the event safety valves are installed before water heaters a check should be made as to whether the safety valve reacts when...

Page 18: ...ith a contact opening width of 3mm is to be provided in the electrical supply line Automatic circuit breakers are also permissible as isolators d The connection cable must be inserted into the connect...

Page 19: ...cold weather season if the device will be out of action for several days and is not being operated in frost protection mode The draining of the domestic water is carried out once the shut off valve ha...

Page 20: ...escale with a wooden instrument and then take out with a vacuum cleaner or wipe it out with a cloth The device must then be thoroughly rinsed in accordance with NORM H5195 and the heating up process i...

Page 21: ...and non functioning operating fittings glass or plastic part breakage any colour differences damage through improper use particularly by failing to observe the operating and assembly instructions oper...

Page 22: ...have been fulfilled This includes for example the mandatory and documented replacement of the anode connection to the correct operating voltage damages arising from improper operation are to be avoide...

Page 23: ...Id no 242440 7 23 NOTES...

Page 24: ...x 03512 700 239 Internet www austria email at E mail office austria email at Austria Email in your area For addresses and telephone numbers of our subsidiaries visit our homepage at www austria email...

Reviews: