![Austria Email eco clever 100 Operating And Installation Instructions Download Page 18](http://html1.mh-extra.com/html/austria-email/eco-clever-100/eco-clever-100_operating-and-installation-instructions_3019937018.webp)
18
Id. no.: 242440-7
In order to allow repairs to be carried out easily and to allow the device to be removed or replaced, it is
necessary to establish the connection to the tank by means of a detachable connection (union). Storage
tank leaks as a result of an improper connection and resulting damage and consequential damage are
excluded from the warranty and product liability.
ELECTRICAL CONNECTION
General information
a) The electrical connection must always be implemented in accordance with the circuit diagram pasted
in to the connection space of the storage tank!
b) Ensure the correct connection voltage!
c) An all-pole isolation switch with a contact opening width of 3mm is to be provided in the electrical
supply line. Automatic circuit breakers are also permissible as isolators.
d) The connection cable must be inserted into the connection space of the storage tank and be prevented
from being pulled out and twisted by a strain relief mechanism.
e) For installation and intrusive interventions into the device, the hot water storage tank must first be
isolated completely (all poles) and on every side from the power supply in compliance with EN 50110
(ÖVE, TAEV). Before carrying out any further work, the system must be secured against the accidental
reconnection of the power supply (remove the fuses, trigger the mains circuit breaker).
Connection diagram
L,N ..... Power supply grid
Connection voltage ~230V
80 litre
2000 Watt
100 litre
2000 Watt
120 litre
2000 Watt
150 litre
2000 Watt
Summary of Contents for eco clever 100