background image

IMGC450

Revision 2.0: August 2021

INTRODUCTION & CONTENTS

Introduction

3

Installing Shock Mount

4

Dimensions

5

Polar Patterns / Frequency Response

6

Specifications

7

Rating plate and caution marking are marked on the back enclosure of the apparatus

WARNING

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH AN EXTENSION CORD, RECEPTACLE 

OR OTHER OUTLET UNLESS THE BLADES  CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE 

TO RAIN OR MOISTURE.

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT 

CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.

The lightning flash with 

arrowhead symbol, within 

an equilateral triangle, is 

intended to alert the user to 

the presence of uninsulated 

“dangerous voltage” within the 

product’s enclosure that may 

be of sufficient magnitude to 

constitute a risk of electric 

shock to persons.

WARNING

TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT 

REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS 

INSIDE. REFER SERVICING 

TO QUALIFIED SERVICE 

PERSONNEL.

The exclamation point  

within an equilateral triangle 

is intended to alert the user 

to the presence of important 

operating and maintenance 

(servicing) instructions in  

the literature accompanying 

the appliance.

For European Union countries: This symbol on  

the product or its packaging indicates that this 

product must not be disposed of with other waste.

Instead, it is your responsibility to dispose of your 

waste equipment by handing it over to a designated 

collection point for the recycling of waste  

electrical and electronic equipment.

Please contact your local authority for further details 

of your nearest designated collection point.

Thank you for purchasing this quality Australian 
Monitor product.

The IMGC450 is the finest gooseneck microphone 
Australian Monitor has released. This premium electret 
condenser microphone is tailored specifically for voice 
reproduction, providing a neutral tone and transparent re-
sponse. The cardioid polar pattern of the IMGC450 provides 
exceptional gain before feedback. Users will enjoy fuss-free 
setup with minimal EQ manipulation, ensuring maximum 
SPL for that all-important presentation.

This premium microphone is highly recommended for 
conference rooms, board rooms, meeting rooms, 
houses of worship, school halls and many other 
presentation applications.

Summary of Contents for IMGC450

Page 1: ...TION AND OPERATION MANUAL IMGC450 GOOSENECK MICROPHONE BOX CONTAINS 1 x IMGC450 Gooseneck Microphone 1 x Isolated shock mount 3 x Self tapping screws for shock mount installation 1 x Windsock Instruction manual ...

Page 2: ...1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs regi...

Page 3: ...EFER SERVICING TO QUALIFIED SERVICE PERSONNEL The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instea...

Page 4: ...ker or punch Using a 3 0mm drill pre drill three pilot holes Insert the shock mount into the hole again and fasten down the shock mount with the 3 screws provided Installing IMGC450 into the Shock Mount To install the IMGC450 into the Shock Mount unscrew the bottom plastic screw collar Slide the IMGC450 body into the Shock Mount Re install the bottom plastic screw collar until snug Be careful not ...

Page 5: ...IMGC450 INSTALLATION AND OPERATION MANUAL 5 DIMENSIONS ...

Page 6: ...IMGC450 INSTALLATION AND OPERATION MANUAL 6 POLAR PATTERNS AND FREQUENCY RESPONSE TYPICAL FREQUENCY RESPONSE TYPICAL POLAR PATTERNS 250Hz 2000Hz 500Hz 4000Hz 1000Hz 8000Hz ...

Page 7: ... Oct SENSITIVITY 7 0 mV Pa 42 dBV ELECTRICAL IMPEDANCE 200 Ω MIN LOAD IMPEDANCE 1000 Ω S N RATIO 72dB A weighted MAX SPL 135dB 1 THD PHANTOM POWER V 9 52 V DC CURRENT DRAW 1 9 mA FINISH Matte Black CONNECTION Balanced 3 pin XLR Male Pin 2 Pin 3 Pin 1 shield OPERATING TEMP 10 C 50 C 95 humidity max DIMENSIONS 450 mm Length NET WEIGHT 151g INCLUDED ACCESSORIES Isolation shock mount windsock ...

Page 8: ...D BY AUSTRALIAN MONITOR Address Unit 1 2 Daydream Street Warriewood NSW 2102 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ABN 86 003 231 187 ...

Reviews: