The CAT5 cable connects to the screw terminals numbered 1-6. These

numbers correspond to the pins of the RJ45 connector on the main

unit. If following the 568A convention, the wire colours are wired as:

P I N

W I R E   C O L O U R

D P   N E T W O R K

1

White/Green

Ground

2

Green

+18V

3

White/Orange

Data+

4

Blue

Busy-

5

White/Blue

Busy+ (+18V)

6

Orange

Data-

7

White/Brown

Spare

8

Brown

Spare

Ensure that the spare pair cannot short to anything.

NOTE: If the Remote Control Panel is NOT the last 

unit in the CAT5 RUN and there are paging stations

connected further down the run it is important that

the spare pair is continued to the next unit otherwise

voice information from the paging stations will not

get to the main DigiPage unit.

There are two holes available adjacent to the terminal block for

securing the CAT5 cable with a cable tie.

“PIN 1”

Summary of Contents for DPRM

Page 1: ...1 Clyde Street Silverwater NSW 2128 Australia 61 2 9647 1411 www australianmonitor com au SERVICE INFORMATION DIGIPAGE DPRM REMOTE CONTROL PANEL CONTENTS OPERATION MANUAL SCHEMATIC DIAGRAM TEST PROCEDURE SERVICE BULLETIN ...

Page 2: ...REMOTE CONTROL PANEL INSTALLATION AND OPERATION MANUAL DPRM ...

Page 3: ...k fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to ...

Page 4: ...olution at a contractor friendly price INTRODUCTION 3 CONTROLS 4 INSTALLATION 5 PROGRAMMING 6 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operation and maintenance s...

Page 5: ...ocal input on or off BUSY This LED lights when the system network is busy The remote control panel is disabled while the system is busy unless it is the panel in use generating the busy indication VOLUME UP DOWN These two buttons increase or decrease the volume within the zone TERMINATING In an RS485 network of which the DigiPage is part of it is important to terminate the last device in the netwo...

Page 6: ... 4 Blue Busy 5 White Blue Busy 18V 6 Orange Data 7 White Brown Spare 8 Brown Spare Ensure that the spare pair cannot short to anything NOTE If the Remote Control Panel is NOT the last unit in the CAT5 RUN and there are paging stations connected further down the run it is important that the spare pair is continued to the next unit otherwise voice information from the paging stations will not get to...

Page 7: ...The remote control panel will beep 3 times indicating it is in program mode The BUSY LED will stay lit while in program mode Press the Up button X times the unit will beep each time Eg for ZONE 4 press 4 times Press the Down button The BUSY LED will go out The remote control panel is now programmed Confirm that the panel is controlling the correct zone NOTE You have approx 2 secs to begin the prog...

Page 8: ...Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au INTERNATIONAL S...

Page 9: ...D VDD C5 1u L1 250uH C2 220u C1 100u FB 4 OUT 8 6 5 IN 7 IC1 LM2594 RD 1 RE 2 DE 3 DI 4 GN 5 DO 6 DO 7 VCC 8 IC2 DS3695 A2 1 A3 2 A4 3 MC 4 GND 5 B0 6 B1 7 B2 8 B3 9 B4 10 B5 11 B6 12 B7 13 5 14 OSC 15 OSC 16 A0 17 A1 18 IC3 16F84 SER 10 P0 11 P1 12 P2 13 P3 14 P4 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC4 74LS165 D1 D4 1N5818 6 5 4 3 2 1 7 6 5 4 3 2 1 A1 A1 PCB6298 PCB6297 MC MC RESET A4 ...

Page 10: ...it 3 Programming the wall unit a Press and hold the reset button b Press and hold both the volume buttons c Release the reset button d The unit should beep 2 times to let you know you are in program mode e Release volume buttons f Press the up button X number of times for zone X e g Press 3times for zone 3 g Press down button to store the value 4 Then select program 1 to program 6 one by one and c...

Page 11: ... Also check that the program off and Local on off selections reflect in the zone for which the wall unit has been programmed note that with every selection there should be a beep indicating the selection ...

Page 12: ...igiPage is part of it is important to terminate the last device in the network CAT5 RUN On the DPRM a jumper is provided for the data transmission to be terminated if that Remote Control Panel is at the end of a CAT5 RUN Please be aware that DPRM panels ship from the factory with the DATA bus terminated If there is more than 1 DPRM or Paging Station on the CAT5 RUN you MUST remove the termination ...

Page 13: ...tralian Monitor Introduction The Australian Monitor Installation Series DPRM Remote Control Panel is a control surface that is designed to be used with the DigiPage Zone Paging and Source Selection System The DPRM allows control over program source selection local input selection and volume control from a remote location LED illumination provides the user with visual feed back if the system is bus...

Page 14: ...LED will stay lit while in program mode 5 Press the Up button X times the unit will beep each time Eg for ZONE 4 press 4 times 6 Press the Down button 7 The BUSY LED will go out The remote control panel is now programmed 8 Confirm that the panel is controlling the correct zone 4 Busy 5 Volume Up Down 6 Terminating This LED lights when the system network is busy The remote control panel is disabled...

Reviews: