![AUSTRALIAN MONITOR DPRM Service Information Download Page 5](http://html1.mh-extra.com/html/australian-monitor/dprm/dprm_service-information_3019734005.webp)
PAG E 4
D P R M I N S TA L L AT I O N & O P E R AT I O N M A N UA L
C O N T R O L S
All the controls correspond only to the zone for which the panel
is programmed by the installer. (see programming section)
P R O G 1 – 6
This row of 6 buttons selects the numbered program source.
They are electrically interlocking meaning that selecting one
source will deselect the previously selected source.
P R O G O F F
This button will turn off the program source that is
currently selected .
L O C A L O N / O F F
This button toggles the local input on or off.
B U S Y
This LED lights when the system network is busy. The remote
control panel is disabled while the system is busy unless it is
the panel in use generating the busy indication.
VO L U M E U P / D OW N
These two buttons increase or decrease the volume within
the zone.
T E R M I N AT I N G
In an RS485 network (of which the DigiPage is part of) it is
important to terminate the last device in the network CAT5 RUN.
A jumper is provided for the data transmission to be terminated
if that Remote Control Panel is at the end of a CAT5 RUN.
Shipped as terminated.
2
3
4
5
1
6
1
2
3
4
5
6
Data
(shown as
terminated)
Holes for
securing cable
Terminal block
for CAT5 wiring
Reset Button