D I G I PAG E 8 M / D I G I PAG E 1 6 M   I N S TA L L AT I O N   &   O P E R AT I O N   M A N UA L

PAG E   5

I N S TA L L AT I O N   &   S E T U P

The CAT5 cable connects to the RJ45 socket on the rear panel of the

paging station. This socket is a NEUTRIKTM connector designed to be

used with the XLR style housing (model NE8MC) to improve reliability.

Normal RJ45 connectors can also be used.

Plugging and unplugging the cable while the system is powered up

may result in the system locking up and is not recommended. If this

should happen, reset the DigiPage by switching off, then on.

G A I N

To accommodate different speech levels, there is a gain control

on the base of the DigiPageM. This ships set to minimum and may

be adjusted to suit. Increasing this control too far may cause the

paging station to distort if loud or close speech levels are

encountered.

T E R M I N AT I N G

In an RS485 network (of which the DigiPage is part of) it is

important to terminate the last device in the network CAT5 RUN.

Two jumpers are provided for the data transmission and the voice

transmission to be terminated if that Paging Station is at the end

of a CAT5 RUN (see diagram).Shipped as terminated.

When making changes be sure to power off the

system and disconnect from the network.

NOTE: these stations are not compatible with the

DigiPageJr network system.

6

B A S E   P L AT E   S E C T I O N

Voice Data

(shown as terminated)

Gain Pot

(accessible through base plate)

7

6

7

Summary of Contents for DIGIPAGE DP16M

Page 1: ...tralian Monitor 1 Clyde Street Silverwater NSW 2128 Australia 61 2 9647 1411 www australianmonitor com au SERVICE INFORMATION DIGIPAGE DP8M DP16M PAGING STATION CONTENTS OPERATION MANUAL SCHEMATIC DIAGRAMS ...

Page 2: ...PAGING STATION INSTALLATION AND OPERATION MANUAL DigiPage8M DigiPage16M ...

Page 3: ...k fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to ...

Page 4: ...T 5 cable and as with all Australian Monitor installation products the Paging Station provides an elegant solution at a contractor friendly price INTRODUCTION 3 CONTROLS 4 INSTALLATION SETUP 5 NOTES 6 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to...

Page 5: ...t does NOT clear the current zone selection configuration so the paging station will return to its previous state selected zones once the ALL PAGE button is released ZONE PAGE This button pages to the current zone selection configuration as indicated by the ZONE select LEDs The zones being paged have their program sources muted and the microphone becomes active If no zones are selected the system ...

Page 6: ...trol on the base of the DigiPageM This ships set to minimum and may be adjusted to suit Increasing this control too far may cause the paging station to distort if loud or close speech levels are encountered TERMINATING In an RS485 network of which the DigiPage is part of it is important to terminate the last device in the network CAT5 RUN Two jumpers are provided for the data transmission and the ...

Page 7: ...PAGE 6 DIGIPAGE8M DIGIPAGE16M INSTALLATION OPERATION MANUAL NOTES ...

Page 8: ...Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au INTERNATIONAL S...

Page 9: ... 100K R19 2k2 R18 10K R17 10K R1 100K R2 47K R3 10K R4 5K6 R5 470R R6 100K R7 47K R8 10K R9 5K6 R10 470R R11 2K V1 BC546 V2 BC546 C1 1u C2 1u C3 1n C4 4u7 C5 22u C6 1n V3 BC546 R12 100R R13 2k2 5 6 4 IC1B 4093 8 9 10 IC1C 4093 V4 BC546 V5 BC546 V6 BC546 V7 BC556 V8 BC556 V9 BC556 R14 1K R15 10K R16 10K C7 120P VDD 1 2 3 4 5 6 7 8 RJ1 1 2 3 4 5 6 7 8 RJ2 RD 1 RE 2 DE 3 DI 4 GN 5 DO 6 DO 7 VCC 8 IC2...

Page 10: ... 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC3 74LS165 SER 10 P0 11 P1 12 P2 13 P3 14 P4 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC4 74LS165 R1 1K R2 1K R3 1K R4 1K R5 1K R6 1K R7 1K R8 1K D1 D2 D3 D4 D5 D6 D7 D8 R17 1K S1 S2 S3 S4 S5 S6 S7 S8 VDD X1 S17 S18 S19 D17 C1 1u C2 1u C3 1u C4 1u VDD A3 CLEAR ZONE 1 ZONE 8 PAGE ALL CALL B6 B5 B3 B7 B0 BUSY B1 B7 1 2 3 4 5 6 7 8 9 10 NC B0 B1 ...

Page 11: ...CLK2 15 PL 1 Q7 9 Q7 7 IC3 74LS165 SER 10 P0 11 P1 12 P2 13 P3 14 P4 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC4 74LS165 R1 1K R2 1K R3 1K R4 1K R5 1K R6 1K R7 1K R8 1K R9 1K R10 1K R11 1K R12 1K R13 1K R14 1K R15 1K R16 1K D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 R17 1K S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 VDD VDD X1 S17 S18 S19 D17 C1 1u C2 1u C3 1u C4 1u V...

Reviews: