Power Output

60 Watts RMS

Maximum Load

160 Ohms @ 100 Volts

Power Bandwidth

60Hz - 15kHz < O.5% THD

Frequency Response

60Hz - 15kHz (± 3dB)

Total Harmonic Distortion

0.5% @ 1 KHz rated power

Signal To Noise Ratio

-74dB with all controls at their centre position

Tone Controls

Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB

Inputs

Four mic/aux universal inputs with XLR female mic sockets and 

dual RCA aux sockets plus an insert point

Input Sensitivity

Mic: 1mV @ 200 Ohms; Aux 1-3: 75mV @ 47K Ohms; Aux 4: 300mV @ 47K Ohms

Outputs

Speaker: 100, 70 Volts, 8 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV

Phantom Power

18 Volts DC on all Mic inputs (rear panel on/off switch)

Speaker Zone Selection

Speaker zone selector, switches 100V line output to 6 separate zones. 

An ”all call“ switch overrides alI zones.

Controls

4 Input channel gain controls, 1 Bass control, 1 Treble control, 

1 Master gain control, 6 Speaker zone selector, 1 Speaker ”all call“ selector, 

Pre-announce defeat switch, Phantom Power on/off switch (on rear panel)

Indicators

Power ”on“ LED

Power Source

AC 230/240V - 50Hz; DC 24V; 110V - 60Hz (special) 3 pin IEC connector

Power Consumption

125 Watts

Protection

Soft limiter for overload and overdrive protection, plus AC and DC fuses

Dimensions/Weight

88mm H x 480mm W x 330mm D (Chassis Dimensions only). 10kg

Rack Mounting

Standard

Tone Generators

Built-in four tone generator module. 

Includes Bell, Pre-Announce, Alert and Evac tones

Muting

Built-in VOX muting. Channels 1 and 2 will mute channels 3 and 4.

Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (

ABN 78 001 345 482

), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia

NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698   VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977   QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237   WA Tel: (08) 9228 4222 Fax: (08) 9228 4233   

SA Tel: (08) 8352 4444 Fax: (08) 8352 4488   NZ Tel: (09) 415 9426 Fax: (09) 415 9864 Export Enquiries: [email protected]   

Website: www.australianmonitor.com.au

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The mixer amplifier shall have four universal input channels, each comprising of a balanced microphone

input with XLR female sockets and an auxiliary input using dual RCA sockets. The 100V line speaker out-

puts should be able to be switched via a six position selector with ”all call.” A balanced XLR output to

drive additional power amplifiers shall also be provided. 

This unit shall offer remote master VCA control, 24V DC and mains power operation, and a vox trig-

gered relay output.

The amplifier master section shall include one master gain control, two EQ controls, one with 12dB of

cut and boost at 100Hz and the other with 9dB of cut and boost at 10kHz. Speaker outputs shall be

transformer isolated at 100V, 70V and 8 ohms. The amplifier must be capable of delivering 60 watts

RMS into an 160 ohm inductive load, with less than 0.5% distortion measured at 1kHz and with system

hum and noise less than -74dB. 

The amplifier shall be an Australian Monitor Installation Series model AMIS60.