Rear Panel Features

AC Power Inlet

The 3 pin IEC power inlet is located on the bottom left of the rear panel and accepts a standard mains power lead  fitted
with an IEC connector. Before plugging in a power lead, please check the rear panel of the amplifier to ensure that the
voltage label shows the correct AC operating voltage for your part of the world.

The inlet is equipped with an in-built AC fuse holder fitted with a 6 Amp slow blow fuse plus a spare fuse. Please
ensure that the mains power cord is disconnected before attempting to check or replace this fuse.
 Power consump-
tion is 400 VA (max).

Speaker Output Terminal Strip

Located on the top left of the rear panel is the speaker output terminal strip. Reading from left to right, the connec-
tions are:

COM

Common or “-” for low impedance speaker loads (4 ohms).

4

The “+” for 4 ohm speaker loads (use with common)

COM

Common or “-” for 70v or 100v speaker loads (maximum load of 40 ohms at 100v)

70

The “+” for 70v line speaker loads (use with common)

100

The “+” for 100v line speaker loads (use with common)

Please ensure that the correct “Common” is used. Low impedance and 70/100v loads can be used simultaneously
but please pay careful attention to the overall speaker load. When used individually, the low impedance load should
be 4 ohms or higher while the 100v line load should not fall below 40 ohms. When both outputs are used
simultanously, ensure that neither output is loaded to maximum.

Level Control

Located to the left of the XLR input/output is a recessed screwdriver adjustable level control. The level control is
an input attenuation control normally used to match the amplifier to a wide variety of input signals. In essence, the
amplifier is designed to receive a 700mv input signal however the level control can be used to increase the level for
lower signals or decrease the level for higher input signals. In normal use, the level control is used as a ‘set and
forget’ master level control for the amplifier.

XLR

1 =   Ground
2 =  +  Signal
3 =  -   Signal

ENGIN EERED  BY AUDIO  TELEX C OMM UN IC ATI ON S PTY LTD  SYDN EY AUS TRALIA

INPUT

GAI N

DC FUSE

10 A  SB

For table or shelf mounting, the rack ears can be removed using a screwdriver. Once the rack ears are removed, please
reinstall the screws.

Rack Mounting

The ACM250P is supplied with rack ears attached to allow mounting within a standard 19” equipment rack. As is the
case with almost all audio products, adequate ventilation and air flow is required. When installing multiple ACM250P
power amplifiers within the one rack, it is recommended that at least one rack unit of ventilation space is left between
every two amplifiers.

Summary of Contents for ACM250P

Page 1: ...ACM250P 250w Power Amplifier Operating Manual POWER ON SIGNAL PROTECT ...

Page 2: ... that the ACM250P is receiving audio signal via its line level input The signal LED is a simple method to trouble shoot installations especially in multi amplifier projects At a glance the signal LED will indicate that audio is reaching the amplifier Protect LED A feature of the ACM250P is high temperature protection In most applications the internal cooling fan will most probably never switch on ...

Page 3: ...r load When used individually the low impedance load should be 4 ohms or higher while the 100v line load should not fall below 40 ohms When both outputs are used simultanously ensure that neither output is loaded to maximum Level Control Located to the left of the XLR input output is a recessed screwdriver adjustable level control The level control is an input attenuation control normally used to ...

Page 4: ...output allowing the input signal to be distributed split to other amplifiers In some projects the same input may be looped through to multiple amplifiers using this method Up to 6 amplifiers can be looped together without any noticeable loss in level A distribution amplifier should be used when more than 6 amplifiers need to be looped The XLR s are wired as follows Pin 1 Shield Pin 2 Hot Positive ...

Page 5: ...at producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or com pletely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be peri odically blown free of foreign matter 14 Do not remove the cover R...

Page 6: ...ey QLD 4006 Ph 07 3852 1312 Fax 07 3252 1237 E mail qld audiotelex com au Adelaide SA NT Sales P O Box 157 Hindmarsh SA 5001 31 Walsh Street Thebarton SA 5031 Ph 08 8352 4444 Fax 08 8352 4488 E mail sa audiotelex com au Perth WA Sales P O Box 404 North Perth WA 6906 299 Fitzgerald Street West Perth WA 6005 Ph 08 9228 4222 Fax 08 9228 4233 E mail wa audiotelex com au Auckland NZ Sales P O Box 512 A...

Reviews: