Troubleshooting Guide
Troubleshooting Guide
1.
D
isplay not showing on the plenum
when turned on /off
Check if the power is connected properly to
RV
Check if the battery of remote controller is
good
Check if the remote controller is turned on
off
Check if the power has good connection
from roof unit to plenum
2.
Cooling not good
Select correct cooling mode and confirm
light
is showing
The set temperature should be lower than
room temperature
There is three minutes delay on compressor
Make sure filters are clean
Select max fan to achieve best performance
Be sure all door and windows are closed
Draw curtains to help reduce incoming
heat
3.
Heating not good
Select correct heating mode and confirm
light
is showing
The set temperature should be higher than
room temperature
There is three minutes delay on
compressor
It needs more time to start heating on an
extremely cold winter day
Make sure filters are clean
Select max fan to achieve best
performance
Be sure all door and windows closed
Curtains should help to introduce cold air
in
E0
Communication fault
E1
Room temperature sensor
Fault in connection to temperature sensor or other damage.
E2
Indoor coil temperature sensor
Fault in connection to temperature sensor or other damage.
E3
Outdoor coil temperature sensor
Fault in connection to temperature sensor or other damage.
E4
Insufficient refrigerant
Capillary tube fracture leads to coolants leakage, compressor fault or sensor failure.
E5
Temperature anomaly-outdoor coil
Temperature too high when cooling or too low when heating. (When cooling, the display of E5 indicates
the outdoor temperature exceeds 68
℃
. It is likely due to the reduction of air flow of the condenser,
poor working of condenser fan or sensor failure; when heating, if the outdoor temperature is higher
than 18
℃
, the external air blower may rotate between on and off. The occurrence of this is not a fault,
but the self-protection of the system for avoiding overheating of the unit.)