| 11
Aussie Eco-Clean Super Indy Operating & Maintenance Manual
2020
FIG. 9
FIG.11
STOPPING THE CLEANER
1
) Switch off the burner by
turning the pressure regulator
to pos. "0" (fig. 7B).
2
) Let the cleaner run with
cold water only for at least
30 seconds to cool down the
boiler.
3
) After using with detergent,
flush out the inlet; place the
detergent suction hose (fig.
9) in a tank of clean water and
let the pump run for 1 minute
with the dosing tap turned fully
on and the lance in detergent
delivery condition.
4
) Stop the cleaner by turning
the selector switch to pos. "0"
(fig. 7A).
5
) Discharge the pressure
from the H.P. hose by pressing
the trigger on the gun
6
)
Disconnect the water clea-
ner from the mains electricity
supply via the omnipolar
switch or by unplugging the
plug from the socket.
7
) Turn off the water supply
tap (fig. 5A).
If the water cleaner is left,
even temporarily, turn it off by
using the omnipolar switch or
by unplugging the plug from
the socket.
Water cleaners with the
“Total Stop” device should
be considered as off when
the omnipolar switch is in
the “O” position or the plug is
unplugged from the socket.
When the water cleaner
is not used, close the safety
device on the handle.(fig.11)
Dry use of the water
cleaner causes serious dam-
age to pump gaskets.
FIG. 7
FIG. 8
USING
THE CLEANER
CONTROL PANEL
A
- On/off switch
B
- Temperature regulator
C
- Detergent control tap (if
available).
D
-
Pressure gauge.
STARTING THE CLEANER
1
) Turn on the water supply tap (fig. 5A).
2
) Connect the water cleaner to the mains electricity supply via
the omnipolar switch or by plugging the plug into the socket.
3
) Start the cleaner by turning the selector switch to pos. 1
(fig. 7A).
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4
) Press the trigger on the gun and begin washing.
5
) To use the cleaner with hot water, turn the temperature regu-
lator (fig. 7B) to the recommended washing values.
For some models turn the ignition switch (fig. 7A) onto the
hot water position before effecting the operations described
in this point.
In water cleaners with the “Total Stop” system, the motor
starts and stops when the lever on the lance handle is actioned
or released.
Do not tie the gun trigger in the delivery position.
IMPORTANT
!
To eliminate any impurities
or air bubbles from the wa-
ter circuit we advise starting
the cleaner for the first time
without the lance and letting
the water run out for a few
seconds.
Impurities could block the
nozzle and cause malfunc-
tion (Fig. 8).
!
!
!
!
!
!
250
bar
150
100
50
200
250
bar
150
100
50
200
°C
140°
212 °
100°
158 °
70 °
284 °
°F
°C
140°
212 °
100°
158 °
70 °
284 °
°F
C
A
B
D
C
A
B
D