Gas Appliance Safety
•
Gas appliances are certified and have a flame safeguard feature to stop gas flow in the event of the flame going
out. Never interfere with this function or replace appliances with a non-certified type.
•
Slide-out kitchens with cookers should only be operated with an annex fully erected. Failing to do so may affect
the safety and operation of the gas appliance.
•
Slide-out kitchens with cookers must only be used with a flexible connecting hose that is disconnected from the
gas bayonet fitting when in its stored position. Under no circumstances permanently connect this appliance.
•
Only approved and suitable gas appliances with flame safeguard systems shall be connected to the gas bayonet
(if fitted).
Removing the Hot Water System Flue Cover
To use your inbuilt Truma hot water system, the external flue covers must be removed prior to starting the unit.
Removing Door Vent Cover
The door vent must be uncovered at any time the caravan is occupied.
First, open the flue dust cover
shown.
Second, remove the Truma
factory cover by placing thumbs
in the middle of the cover and
pulling the top towards you with
your fingers.
The flue should look like this
when ready to use