INSTALLATION – NOTES TO THE INSTALLER
APPLIANCE MUST BE INSTALLED ONLY BY A LICENSED GASFITTER OR
PLUMBER.
INSTALLATION
Position of Wok Cooker outlet pipe at the rear of the unit:
RB18 / CK801
RB28 / CK802
SAFETY PRECAUTIONS
MAKE SURE YOU AND YOUR LICENSED GAS FITTER/PLUMBER CAREFULLY READ ALL OF THESE
INSTRUCTIONS BEFORE INSTALLING THE COOKER. FOLLOW ALL WARNINGS AND
INSTRUCTIONS MARKED ON THE COOKER.
Do not install a damaged cooker. Contact your service agent or supplier if the cooker is
damaged.
Check the gas type of the cooker and make sure it is suited for the type of gas supplied.
Make sure the gas inlet pipe is clean and not blocked before connecting the gas.
Selecting a suitable position for the cooker is important to ensure maximum performance,
economy and safety of operation.
Always ensure that adequate fresh air is provided for ventilation.
The cooker must only be operated on a level, firm non-combustible surface.
This cooker shall not be installed in a position where it could create a fire hazard and the
minimum clearances to combustible materials must be observed, as described below.
SERVICE INSTRUCTIONS FOR LISCENSE GAS FITTER OR PLUMBER.
(a) Remove all covers and other parts for access to all components.
(b) Remove all components for services.
CLEARANCES
This cooker must be installed so that a vertical clearance of at least 1200mm is maintained
between its burners and any combustible material. Where it is not practical, the underside of
any combustible material with a vertical clearance of less than 600mm above a burner should
be protected by mill-board at least 6mm thick which is covered with sheet metal not less than
0.4mm thick, or protected by an equivalent material extending at least 225mm beyond the
sides of the cooker. In either case, the vertical clearance above the cooker burner should not
be less than 450mm.
The minimum clearance from the cooker to rear or sides of combustible surfaces must be no
less than 250mm. When the cooker is installed abutting a side or rear wall, the wall must be of
non-combustible material, e.g. ceramic tiles. If surrounding walls are constructed with a
combustible material, contact your local Gas Authority for information on clearances required.
Combustible material
Range hood