background image

AUSCROWN

BRUSHED STAINLESS STEEL
CANOPY RANGE HOODS

Features:
Strong Suction / Brushed Stainless Steel Body / 3 Speed Control / 
Micromesh Filters /Optional Charcoal Filter / Ducted or Re-circulated Exhaust

CS900 900MM

CS600 600MM

CI900G 900MM ISLAND TYPE
WITH TEMPERED GLASS

CI900 900MM ISLAND TYPE

C900GH 900MM CANOPY 
WITH TEMPERED GLASS

X: Heigh when duct cover fully extended.

Model

C900GH

CS900

CS600

CI900

CI900G

Dimensions

W900mm

D475mm
H560mm

X950mm

W900mm

D480mm
H520mm

X910mm

W600mm

D480mm
H520mm

X910mm

W895mm

D600mm
H637mm

X1204mm

W895mm

D600mm
H613mm

X1180mm

Net Weight

21kg

22kg

17kg

27kg

29kg

Lamp Power

Flow Rate

Load of Motor

Duct Size

C tick Approval

AS Approval

Power

No. of Motor

240V 60Hz

1

V06076/0

N2788

1000m³/hr

2 x 2W

Ø150mm

4 x 2W

250W

Summary of Contents for CK801NG

Page 1: ... greater cooking flexibility Easy to clean stainless steel top and control panel IMPORTANT The appliance must be installed only by an authorised person such as a licensed gas fitter or plumber Read this manual carefully and retain for future reference THE APPLIANCE MUST BE INSTALLED IN COMPLIANCE WITH THE FOLLOWING AS5601 Australian Standard for Gas Installations Manufacturer s installation instru...

Page 2: ...ooker and its effect on surrounding surfaces clothing and skin Children or the elderly should be supervised when near this appliance Do not hang clothing or other flammable material on or near this appliance Do not cover or blow out the flames This could cause gas leaking Always keep flammable materials away from the cooker Do not store things close to the cooker Install and use the cooker in a we...

Page 3: ... minimum clearances to combustible materials must be observed as described below SERVICE INSTRUCTIONS FOR LISCENSE GAS FITTER OR PLUMBER a Remove all covers and other parts for access to all components b Remove all components for services CLEARANCES This cooker must be installed so that a vertical clearance of at least 1200mm is maintained between its burners and any combustible material Where it ...

Page 4: ...s Screw the brackets securely to the bench top using the appropriate nut and screws 6 7 Check for gas leakage at all joints with soapy water or other approved methods SAFETY INSTALLATION OF THE REULATOR AND HOSE ASSEMBLY 8 The installation of the regulator and hose assembly must follow the Australian Standard AS5601 9 The regulator and hose must be AGA approved 10 The hose and regulator should not...

Page 5: ...e flame is normal when adjusted to low flame there should be no yellow flames at anytime 4 Check there is no backfire when the appliances is turned down to low or turned off 5 The main gas supply valve is off 6 The gas control on the appliance is off 7 The consumer fully understands the safety precautions operation and maintenance 8 The operation of the ignition system is satisfactory 9 If a norma...

Page 6: ... Trivet 4 Inner Ring Brass Cap 6 Burner Head 8 Knob OPERATING INSTRUCTIONS USING THE COOKER Follow these steps when operating the cooker LIGHTING THE COOKER 1 Make sure the ignition knob set to the OFF position 2 Push in and turn the ignition knob anti clockwise until a click sound is heard Make sure the burner has been lit properly ADJUSTING THE FLAME 1 Turn the ignition knob to the required flam...

Page 7: ... head and burner cap with a moist and soaped sponge or cloth Do not put them in cold water immediately after use as thermal shocks could cause cracking CLEANING VENTURI OR INJECTOR BLOCKAGE FOR LICENCED GAS FITTER ONLY 1 Turn off main gas supply 2 Disconnect regulator or hose from gas supply 3 Remove all trivet s tray s and Burner Caps CK801 802 only 4 Turn over the cooker 5 Remove the clip that h...

Page 8: ...l air in the hose is purged completely Clean and wipe the electrode with a dry cloth Push in the ignition knob and turn it anti clockwise until a click sound is heard Ensure the burner has been lit Press the ignition knob for 3 4 seconds and release the knob Gas Leaking Failure of the gas valve Contact your dealer for a service repair DO NOT ATTEMPT TO REPAIR IT YOURSELF Incomplete Combustion Yell...

Page 9: ......

Page 10: ...converted for use on any other type of gas for further advice contact place of purchase or their authorised agent for advice SERVICE INSTRUCTIONS FOR LISCENSE GAS FITTER OR PLUMBER a Remove all covers and other parts for access to all components b Remove all components for services ...

Page 11: ...E Gas Pressure kPa 1 00 2 75 Gas Fitting BSPM 60 0 coned Ignition System Piezo electric Country of Origin China AGA Approval No 7092G Austcrown Pty Ltd and their appointed agents will not be liable in respect of any misuse which is not in accordance with the instructions and precautions specified in this booklet AUSTCROWN PTY LTD Website www auscrown com au SERVICE AGENTS For services and repairs ...

Page 12: ......

Page 13: ...AUSCROWN www auscrown com au ...

Page 14: ...40mm Pilot Indoor Outdoor Indoor Outdoor 2 75kPa 1 0kPa 2 75kPa Ø0 90mm Ø0 50mm Ø0 90mm Ø0 50mm Ø1 65mm Ø0 7mm W720mmxD382mmxH145mm 6 53kg Piezo Electric 1 4 BSPM 60º Coned Propane Gas Propane Gas 1 0kPa Natural Gas Ø0 7mm Ø1 65mm Inlet Fitting Country Of Origin Dimensions Natural Gas W292mmxD382mmxH145mm 3 41kg 7092 China Model Heat Capacity AGA Approval No Net Weight Ignition System Gas Type Gas...

Page 15: ...AUSCROWN STAINLESS STEEL TABLE FOR COOKER STAINLESS STEEL TABLE FOR COOKER Max Load 50kg Model SB602 Gross Weight Dimensions Overall 6 7kg W720mmxD520mmxH812mm Can be used with Handy Range Single Wok Burner Double Wok Burner Rice Cooker High Pressurer Wok Burner Portable Cast Iron Burner SB602 DISPOSABLE POL SEAL Install Remove ...

Page 16: ... Steam function Enameled pan Grill plate lifter included Grill plate lifter included For convenient and safe handling How it works Steam action Keeps food moist succulent when cooking Enamelled pan Collects excessive grease and reduces smoke Handy Range Not Included Removable non stick grill plate Makes cooking and cleaning easy KW707 BUTANE GAS BLOW TORCH Product name Butane gas blow torch Model ...

Page 17: ...0MM ISLAND TYPE C900GH 900MM CANOPY WITH TEMPERED GLASS X Heigh when duct cover fully extended Model C900GH CS900 CS600 CI900 CI900G Dimensions W900mm D475mm H560mm X950mm W900mm D480mm H520mm X910mm W600mm D480mm H520mm X910mm W895mm D600mm H637mm X1204mm W895mm D600mm H613mm X1180mm Net Weight 21kg 22kg 17kg 27kg 29kg Lamp Power Flow Rate Load of Motor Duct Size C tick Approval AS Approval Power...

Page 18: ...TE WITH HOSE REGULATOR RBC176LP RBC225LP 20MJ hr 32MJ hr 0 42kg hr 0 64kg hr Inner Ring Ø0 65mm Ø0 90mm Outer Ring Ø1 20mm Ø1 30mm Pilot Ø0 60mm Ø0 6mm W290mm x D540mm x H130mm W350mm x D600mm x H140mm 5 16kg 6 6kg Approval No IAPMO R T OCEANA GMK10042 Net Weight Inlet Fitting 1 4 BSPM 60º Coned Country of Origin ULP gas 2 75kPa Piezo Electric China Injector Size Gas Consumption Model Gas Pressure...

Page 19: ...ing Ø0 90mm 3rd Ring Ø1 20mm 1st Ring Ø0 50mm 2nd Ring Ø0 80mm 3rd Ring Ø1 05mm 4th Ring Ø1 50mm Dimensions W190mm L370mm H85mm W185mm L420mm H85mm W250mm L470mm H95mm W360mm L635mm H110mm Net Weight 1 82kg 3 2kg 6 2kg 12 8kg Gas Type Gas Pressure Ignition System Inlet Fitting AGA Approval No 6429 Propane Gas 2 75kPa Manual 1 4 BSPM60º Coned Supplied with AGA approved regulator 1 2 meter hose FF30...

Page 20: ...OUTDOOR USE ONLY Features Portable Ideal for Outdoor Cooking Double Ring Burner Supplied with Hose and Regulator Ring Burner Country Cooker JZDD17 PIEZO ELECTRIC IGNITOR Model GB01LP GB02LP GB03LP Heat Capacity 12MJ hr 2 x 12MJ hr 3 x 12MJ hr Gas Consumption 0 26kg hr 2 x 0 26kg hr 3 x 0 26kg hr Dimensions mm W270 x D350x H140 W520 x D350 x H140 W770 x D350 x H140 Net Weight 3 20kg 5 5kg 8 7kg Gas...

Page 21: ...sions mm Injector Size No of jets Pot Size mm Net Weight Ignition System Inlet Fitting China 44kg W550 x D560 x H445 495 27kg Min Ø440 Max Ø490 GASMARK CERTIFICATE GMK10005 W680 x D700 x H520 570 Min Ø440 Max Ø610 18 28 Piezo Ignition with Pilot 1 2 BSPF with Flame Failure Safety Device with Flame Failure Safety Device Model HP200LPWF HPA100LPWF Gas Pressure 61kPa 100kPa Heat Capacity 64MJ hr 55MJ...

Page 22: ...MJ hr 77 0MJ hr 118 2MJ hr 144 5MJ hr Gas Consumption 0 5kg hr 0 88m hr 0 95kg hr 1 52m hr 1 18kg hr 2 03m hr 2 37kg hr 3 81m hr Nozzle Size Ø0 58mm Ø1 10mm Ø0 58mm Ø1 10mm Ø0 58mm Ø1 10mm Ø0 58mm Ø1 10mm Dimensions mm Net Weight Ignition System Flame Failure Safety Inlet Fitting Country of Origin 1 2 BSPM Piezo Electric W430 x L720 x H300 6kg 8 5kg 14kg 32kg Taiwan 1 4 BSPM 60º coned Mushroom sto...

Page 23: ...e Propane Gas Natural Gas Gas Pressure 2 75kPa 1 00kPa Gas Consumption 1 4kg hr 1 8m hr Injector Size Outer Ring Ø1 90mm Outer Ring Ø3 10mm Heat Capacity Inlet Fitting Dimensions Net Weight Approval Country of Origin 70MJ hr China CRN8 Dual Ring Burner W250mm x D405mm x H80mm 7 1kg Gas Fitter Applied 1 4 BSPM Injectors Product Name Gas Type Propane Natural Propane Natural Propane Natural Propane N...

Page 24: ... Large Cooking Capacity Keep Warm Function ERC6 9L ERS5L Non Stick Inner Bowl ERS5L only Aluminium Inner Bowl ERC6 9L only Rice Net MADE IN KOREA MADE IN KOREA MADE IN TAIWAN MADE IN TAIWAN Features Cook up to 30 cups of rice Cook Auto switch to keep warm Side elements for even cooking and warming Premium hard wearing Teflon coating with heavy gauge cooking bowl Easy clean non stick inner bowl Pol...

Page 25: ...A510 POL with O Ring CGA510 POL with O Ring Product name Stainless steel braided high pressure LP gas hose Model HM12 HM15 HM18 RHS005 Length 1200mm1500mm1800mm 1800mm Inlet Fitting 1 4 BSPM Outlet Fitting 1 4 BSPF Swivel Nut Max Working 2600kPa Working Country of Origin 7kPa 20ºC to 65ºC Low pressure LP gas hose 3 8 BSPM 1 4 BSPF Swivel Nut China Model M12P14S M18P14S Hose Length 1200mm 1800mm In...

Page 26: ...FB06 FB2 FB1 5 Heat Capacity 200 98 58 8 29 4 19 6 14 7 Gas Consumption 4 1kg hr 2 0kg hr 1 2kg hr 0 6kg hr 0 4kg hr 0 3kg hr Jet Size Ø1 55mmØ1 00mm Ø0 60mm Ø0 55mm Ø0 35mm Ø0 25mm Burner Diameter 42mm 32mm 29mm 25mm 19mm 18mm 51mm 38mm Length 108 91 87 84 70 67 113mm 103mm Net Weight 0 21 0 12 0 11 0 09 0 08 0 07 0 23kg 0 16kg Gas Type Gas Pressure Inlet Fitting Recommended 400kPa Internal M20x1...

Page 27: ...4 44cups 24 56cups 24 44cups 24 56cups Heat Capacity 9 0MJ hr 21 5MJ hr 28 5MJ hr 32 5MJ hr 36 5MJ hr 31 8MJ hr 36 5MJ hr Gas Consumption 0 18kg hr 0 43kg hr 0 57kg hr 0 65kg hr 0 73kg hr 0 84m hr 0 96m hr Dimensions Ø390mm H330mm Ø470mm H420mm Ø540mm H460mm Ø590mm H460mm Ø590mm H490mm Ø590mm H460mm Ø590mm H490mm Net Weight 5 9kg 12 8kg 16 2kg 16 2kg 19 0kg 16 2kg 19 0kg Flame Failure Safety Devic...

Page 28: ...omatic Pulse Ignition Power DC 3V Water Pressure 0 025 1 0 Mpa Water Inlet size G1 2 Dimensions H 440mm x L 330mm x W 130mm Gross Net Weight 6 6kg 6 0kg Country of Origin China AT204 STAINLESS STEEL CABINET COOKER HQ204 POWDER COATED CABINET COOKER Low pressure High pressure AT402 LF402 SA820 SA920 SA810 AUSTCROWN PTY LTD VICTORIA AUSTRALIA Shop online www auscrown com au LF402 AT402 SA810 SA820 S...

Reviews: