SPECIFICATIONS 

Model

 

AU1000DD

 

Power supply

 

AC 220-240V, 50Hz

 

Power input  

Low 410watts / High 720watts 

Dehumidifying capacity

 

10 litres/day 

(20°C@60%RH)  

Recommended room size 

50m

or 125m

3

 

Capacity water container

 

3.8 litres

 

Operating range

 

1 – 40°C

 

Dimensions (w x d x h)

 

W462 x D217 x H525mm

 

Noise levels  

Low 45, High 52 dBA 

Power control 

Easy soft touch 

Desiccant 

Zeolite 

Drain hose 

1.2M provided 

Net weight

 

8.2kgs

 

For all after-sales enquiries and warranty details please visit our website 

for contact information, or call 1800 122 100 

Summary of Contents for AU0700DD

Page 1: ...USER MANUAL Ausclimate Cool Seasons 10L Desiccant Dehumidifier Model AU1000DD Please read this user manual before operating ...

Page 2: ...ks do not immerse unit power cord or power plug in water or spray with liquids 11 Never unplug the power cord without pressing the ON OFF key to off first as this could damage the unit 12 Always unplug the unit when not in use or moving location To disconnect from the power supply grip the plug to pull from the power socket Never pull by the cord 13 Always empty the water tank before storing the u...

Page 3: ...ain performance Laundry mode includes power saving setting for warm temperatures turbo setting for winter Up to 8 hour timer for added convenience Temperature range for use 1 C 40 C Light portable with carry handle Removable water bucket with handle Operating light Auto restart after power cut Once the power is restored after a power failure the appliance will continue to operate at the selected s...

Page 4: ...ut the bucket Bucket Full Check ON OFF Wide Front Up 8H 4H 2H Turbo Saving High Low Auto TIMER SWING DRY MODE LAUNDRY MODE Louver settings Control key Dry Mode key Power Key Continuous Laundry Mode key Timer key Timer indicators Function indicators Louver setting indicators Water Full indicator Indicator lights up when the bucket is full of water orincorrectly installed Check indicator Indicator l...

Page 5: ...ere central such as the middle of the room or a hallway Do not position in front of a radiator or in direct sunlight TO OPERATE SAFELY Do not insert small objects into the unit as they may cause damage or possible hazard Keep suitable distance space as above Do not remove water bucket when running or water may leak Ensure water bucket is fitted correctly If the bucket is full or is not in place th...

Page 6: ...Y MODE Press the AUTO DRY key for dehumidification general drying of your home or office Note There may be times when the fan speeds are the same for AUTO and LOW AUTO itself is not a fan speed but a target relative humidity set point that uses either the low or high fan speeds to reach its target of 55 60 RH If the relative humidity of the room is close to or within this range then switching betw...

Page 7: ...ess the SWING Key to select the preferred air louver angle UP FRONT HOLD LED OFF The louver modes are useful for speeding up the drying of washing wardrobes and walls because it directs the airflow towards the surface of these areas water molecules will be forced out faster SAVING TURBO MODE DESCRIPTION UP The automatic louver swings in an upward range of approx 100 0 The automatic louver swings i...

Page 8: ... hours lights will indicate the time remaining When no TIMER is set the LED light is off the unit will run continuously unless the bucket is already full 4hrs continuous LED OFF The Timer mode is useful A sub louver under the main louver can be moved out for blowing air downward further if you want to dry a load of washing in Turbo laundry mode and you know that it will take say 4 hours and you wi...

Page 9: ... included 1 Use a screwdriver to remove the knockout at the back of the unit Attach the tubing to the connector through the hole 2 The drain hose should lead downwards away from the unit with no sharp bends to ensure uninterrupted drainage 8 cannot work correctly into position Return the cover and the handle 1 When the water bucket is full the FULL LED lights up and the unit stops within a few min...

Page 10: ... the unit may be affected Check and clean the filter every 2 weeks or as required 1 Turn off the unit and remove the filter from the unit 2 Clean the filter with a vacuum cleaner 3 You may also wash the filter with water and still retain bacterial protection 4 Replace the filter in position Before placing into storage 1 Turn off the unit wait for it to stop and unplug from the power socket 2 Clean...

Page 11: ...h a greater capacity or compressor dehumidifier There are too many sources of moisture showers washing clothes drying and cooking all puts moisture into the air Un flued gas heating can also add too much moisture into the air for a dehumidifier to remove We recommend using a dehumidifier with a greater capacity or compressor dehumidifier Consider using a different heat source to an un flued gas he...

Page 12: ...om size 50m2 or 125m3 Capacity water container 3 8 litres Operating range 1 40 C Dimensions w x d x h W462 x D217 x H525mm Noise levels Low 45 High 52 dBA Power control Easy soft touch Desiccant Zeolite Drain hose 1 2M provided Net weight 8 2kgs For all after sales enquiries and warranty details please visit our website for contact information or call 1800 122 100 ...