You have successfully deleted a user card.  

 

You can continue to show other user cards, you wish to delete 

 

Other features:-  

1.  Auto 

– alarm will be activated when you input the wrong password 4 

times and the lock will be dead for 1 min.  

2.  Automatic power shortage prompt:- The lock will emit 3 beeps implying 

low battery and the battery needs to be changed. The lock cannot be 
operated when the battery voltage is very low.  

3.  The last password will not be lost in case of battery change.  
4.  Emergency power supply: - When the battery is too low and lock cannot 

be operated. You can connect the USB port with an external power 
supply and operate the lock to open and replace the batteries.  

5.  In case the management card is or all cards need to be deleted press the 

reset button and the passwords will be reset to factory settings.  
 

I. Tips 

Problem

 

Cause

 

Solution 

 

After entering the 
password, the lock 
beeps 3 times.  

 

Battery voltage is too 

low

 

Replace the batteries 

 

After entering the 

password once, one 

beep is heard and the 

green light is on, and 

the lock cannot be 

opened 

 

The latch is not in 

the lock body. 

 

Adjust the position of the lock body.  

 

The lock makes no 

sound but the lock can 

be opened 

Buzzer malfunction 

 

Change the buzzer. 

 

Summary of Contents for PN-19RF

Page 1: ...on 2 1 Unlocking Modes 2 Getting Started 2 1 Unlock and lock using card and password 3 2 How to Change Password 3 3 Adding Management Card 4 4 Adding User card 4 5 Delete cards 4 5 Other features 5 6 Tips 5 User s Manual PIN RFID CABINET LOCK PN 19RF ...

Page 2: ... 5 MHz is also available on order General Introduction ________________________________________________________________________ B Getting Started Please insert 4 AA batteries The product will be given to you in demo mode the default password is 1234 ok and the factory default management password is 12345678 OK Touch Panel Card Inductive Zone USB Key Interface Reset ...

Page 3: ...ock Note in case the card is unverified you will hear 3 beeps D How to Change Management password Input the current management password 12345678 C You will hear a beep and the green light flashes quickly Enter the new Management password you wish to set Press Ok You will hear a beep implying that you have successfully changed the password Verify the working with the new password while the drawer c...

Page 4: ...r card you want to add This will be your User card You will hear a beep implying that you have successfully added the user card You can continue adding card if you wish to add more NOTE You can only add upto 27 user cards H Delete all cards all cards Input the current management password Press C You will hear a beep and the green light will start to flash Press ok Low voltage indicator will start ...

Page 5: ...supply When the battery is too low and lock cannot be operated You can connect the USB port with an external power supply and operate the lock to open and replace the batteries 5 In case the management card is or all cards need to be deleted press the reset button and the passwords will be reset to factory settings I Tips Problem Cause Solution After entering the password the lock beeps 3 times Ba...

Reviews: