installation
and
user
manual
aurora
suspended
fires
09
08
pLanninG
2
FRESH
AIR INTAKE
Fresh air is important. The air supply has to be sufficient
to keep the smoke moving up the chimney. If the heater
is starved for air the draw will weaken and the unit will
leak smoke back into the room. This is a health hazard.
For optimum functioning, we recommend a fresh air
intake in the room. We recommend deflect-O A0684
semi rigid aluminium duct.
minimUm
frESh
air
intakE
SizE
:
MINIMUM TOTAL
FLUE LENGTH
SUSPENSION BRACKET
LOWER ACTIVE FLUE
DAMPER HANDLE
INTERNAL ROTATION ASSEMBLY
FIREBOX
GRATE
ASH REMOVAL TRAY
To guarantee efficiency the minimum total flue length
(lower & external triple skin flue combined) is 15ft.
measured from the point the firebox joins the flue to
the top of the external flue.
Important:
this fresh air intake is compulsory when
operating venting appliances such as kitchen hoods,
permanent air extractors or any appliances creating an
air depression in the habitation.
FRESH AIR INTAKE
OR
31
̎
2
Ø 6
̎
AIR DUCT