installation
and
user
manual
24
installation
3
Aurora Fires must be connected to a chimney & anti-
downdraft cowl complying with the requirements
for Type HT chimneys in the standard for Chimneys,
Factory-built, Residential Type and Building Heating
Appliance, UL 103 / ULC S629. For example, a class A
insulated stainless steel flue chimney system with an
6-inch minimum inside diameter.
The chimney manufacturer’s installation instructions
must be followed precisely. Always maintain the proper
clearance to combustibles as established by the pipe
manufacturer. This clearance is usually a minimum of
2͈ , although it may vary by manufacturer or for certain
chimney components.
EXTERNAL FLUE