www.auroramm.com
USERS GUIDE
RXT-4 Rear Panel Features
LAN
– 10/100/1000 Mbps Ethernet control interface. PoE (802.3at Type 1) interface for
powering unit.
USB Type-C
– Supports HID and storage devices
RS-232
– RS-232 serial connection which can be configured and addressed via a ReAX
control program.
Signal Label
Signal
TX
CH1 Transmit
RX
CH1 Receive
GND
Signal Ground
TX
CH2 Transmit
RX
CH2 Receive
IR
– Ports for IR control which can be configured and addressed via a ReAX control program.
Signal Label
Signal
1
CH1
GND
Signal Ground
2
CH2
Digital
I/O
– General Purpose I/O. The function of the GPIO pins can be configured in the Digital I/O Settings section
of the RXT Setup menus.
Signal Label
Signal
1
CH1
GND
Signal Ground
2
CH2
Relay
– Relay connections for external control which can be configured and addressed via a ReAX control program.
Signal Label
Signal
1
CH1
2
CH2