Inside US: +1 (877) 432-9908
Bulletin No. G10-F
Outside US: +1 (717) 767-6511
Drawing No. LP0909
www.redlion.net
Released 2017-03-30
-1-
Model
G10
‐
Graphite®
10"
Color
Touchscreen
Operator
Interface
Terminal
Installation
Guide
C
US LISTED
UL
R
IND. CONT. EQ.
34AD
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
Class II, Division 2, Groups F and G
Class III, Division 2
T4
C
US
UL
R
LISTED
IND.CONT. EQ.
3PWL
II 3 G Ex ic nA IIC T4 Gc
II 3 D Ex tc IIIC T135°C Dc
-20°C
≤
T
AMB
≤
60°C
DEMKO 14 ATEX 1387X
IECEx UL 15.0035X
See the Red Lion website at www.redlion.net or the
enclosed USB thumbdrive for full user manual, Crimson®
software and software manual.
SAFETY
SUMMARY
All safety related regulations, local codes and instructions that appear
in the manual or on equipment must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment
connected to it. If equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially
harmful to persons or equipment in the event of a fault to the unit.
ORDERING
INFORMATION
SPECIFICATIONS
POWER
:
Must use a Class 2 circuit according to National Electrical Code
(NEC), NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1
WARNING - EXPLOSION HAZARD - DO NOT D
EQUIPMENT UNLESS POWER HAS BEEN SW
OR AREA IS KNOWN TO BE NON-HAZARDOU
CAUTION: Risk of Danger.
Read complete instructions prior to installation
and operation of the unit.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF
OR AREA IS KNOWN TO BE NON-HAZARDOUS.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF
OR AREA IS KNOWN TO BE NON-HAZARDOUS.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2.
DESCRIPTION
PART NUMBER
10" Color Touch Screen, Indoor Use
G10C0000
10" Color Touch Screen, Indoor Use, Additional Ethernet Port
G10C1000
10" High Resolution Display, Color Touch Screen, Indoor Use
G10R0000
10" High Resolution Display, Color Touch Screen, Indoor Use,
Additional Ethernet Port
G10R1000
10" Color Touch Screen, Indoor/Outdoor Use
G10S0000
10" Color Touch Screen, Indoor/Outdoor Use, Additional
Ethernet Port
G10S1000
G10C/R
G10S
Input Voltage 10V
24V
30V
10V
24V
30V
Typical Power HMI only:
10 W 11 W
11 W
15 W 16 W 16 W
Maximum Power HMI only:
15 W 16 W 17 W 20 W 21 W 22 W
Available Power for Modules:
29 W
29 W
Max Power HMI With Module(s):
44 W 46 W 47 W 50 W 51 W 52 W
10.84 (275.2)
8.57
(217.7)
2.06 (52.4)
8.8
(224)
(MOUNTING CLIPS INSTALLED)
11.1 (281)
2.97 (76)
Module sold
separately
DIMENSIONS
In
inches
(mm)