9
RESET – Deregistering all devices paired
with the RT receiver
Signalling operation and reception
of data packet
In order to deregister all devices paired with the RTH receiver, simultaneously press both
the pairing and the deregistering button ( and ) and hold them for at least 5 seconds
until the LED flashes alternating red and green. Then release both buttons
A properly completed process of deregistering all devices is signalled after approx.
2 seconds by the LED colour changing to green and then switching it off for a short
period of time.
Each radio transmission received by the
AURATON RT
receiver from the paired device
is signalled by a temporary change of LED colour to orange. Switching on the relay
is signalled by the LED lit red, whereas switching it off is signalled by the LED lit green.
In the event of an error during the deregistering process, repeat steps 1 and 2. Should
more errors occur, deregister all paired devices (see “RESET – Deregistering all devices
paired with the RT receiver”) and attempt to pair the device again.
NOTE:
If after executing the RESET function the RT receiver is disconnected from power
supply and then connected again, the receiver will automatically enter “pairing” mode
for 120 seconds. A newly purchased RT receiver without any factory-paired devices
(i.e. not the one bundled with the regulator) will behave the same way.
ATTENTION
:
Pressing any button is signaled by a short beep.
2.
Press the pairing button ( ) placed on the rear side of housing and hold it for about
2 seconds. When LED diode ( ) will starts flashing red stop pressing the button.
3.
A properly completed deregis-tering process is signalled by the LED on the
AURATON RT
receiver no longer flashing red and the receiver reverting back to normal operation.