Description of the controller

+

Temperature, 

settings display, etc.;

Operation

indicator

lights;

Function button

/network switch;

Function button

/operation modes;

Temperature

sensor;

Power supply 

wire

Pump control

output;

First start

2)

  Software version (e.g. 1.0).

 

– DHW pump 

4) 

Current temperature of the sensor.

On the left side under the display there is the network switch button (

    

). 

~

Hold the button for 2 seconds to switch the controller on or off. When the 
controller is on, the LED is illuminated red and when it is off, the LED is 
illuminated green. 
After the controller is switched on, the following sequence of information 
is shown on the display: 

 

 

– CH pump

The sensor is ready to set the appropriate operating temperature.

3) 

Controller operation modes. 

1)

  Display test (all segments are on).

The temperature value will then blink for 5 seconds on the display. The 
appropriate temperature can then be set using the (

 – 

) or (

 

+

 

) button. 

After the setting has been performed, the controller automatically stores 
this value and the display shows the current sensor temperature.

The temperature setting function can be activated by briefly pressing the 
left or right button. 

Setting the temperature

The change of the operation mode is saved automatically.

The controller can be set in one of two operation modes.
In order to check the controller’s operation mode, press and hold both 
the (

) and the (

+

) button for 2 seconds. The following information will be 

shown on the display:

 

– 

controller in the CH pump operation mode;

 

– 

controller in the DHW pump operation mode

.

The  operation  mode  can  be  changed  by  simultaneously  pressing  and 
holding both the (

) and the (

+

) button for 4 seconds. The display will 

show  the  blinking  symbols  “

”  or  “

”.  When  this  information

CoO

CuU

is displayed, you can change the mode by pressing the (

) or (

+

) button.

Setting the controllers' mode of operation.

Summary of Contents for S08

Page 1: ...S08 USER MANUAL EN www auraton pl ...

Page 2: ...ntroller s sensor measures the temperature of the water on the supply side of the CH system In a CH system with a coal fired boiler the controller switches off the circulation pumpaftertheflameintheboilerisextinguished TherangeofsettingsfortheCHpumpsisfrom20 Cto90 C Can be used as a DHW pump controller In domestic hot water DHW systems the controller pump assembly forces circulation of water in DH...

Page 3: ...unding tothe terminal ź After the wires have been secured to prevent accidental pulling connectthepowersupplycabletoa230V 50Hzpoweroutlet Connectingthecontroller NOTE The sensor must not be immersed in liquids or installed at fluegasoutletstothestack Mountingthecontroller ź Connecttheblueconductor zeroconductor tothe N terminal ź The controller must be mounted on a wall or another support using tw...

Page 4: ...h Function button operation modes Temperature sensor Power supply wire Pump control output First s 2 Softw 4 Curre On the l Hold the controll illumina After th isshown Thesen 3 Cont 1 Displ The tem appropr After th thisvalu The tem leftorri Settin Thecha Thecon In order the a showno The ope holding show th isdispla Settin ...

Page 5: ...thenbesetusingthe or button After the setting has been performed the controller automatically stores thisvalueandthedisplayshowsthecurrentsensortemperature The temperature setting function can be activated by briefly pressing the leftorrightbutton Setting the temperature Thechangeoftheoperationmodeissavedautomatically Thecontrollercanbesetinoneoftwooperationmodes In order to check the controller s...

Page 6: ...40 C the pump will be switched off when the temperature exceeds 42 C and will be switched on when Setting of the hysteresis To do so function andthe The con DHWpu NOTE The pum controll In order for2sec Manu of the Indic Automa ofthep Manual thepum Disabling the pump alarm softwareVersion1 2andlater The display will show for 5 seconds the blinking operation mode of the controller CO or CU and then ...

Page 7: ... is reached the pump will switch off After the temperature drops below 90 C thepumpisswitchedonagain The pump continues to work regardless of the temperature set on the controllerandtheactualtemperatureinthelocationofthesensor In order to switch the pump off press and hold the right button 2 for2secondsagain Manual switching on and off of the CH or DHW pump Indication of operation of the pump Auto...

Page 8: ...tched on The pump has been switched off waiting for the power supply to be temporarily disconnected COmode thepumphasbeenswitchedon CUmode the pump has been switched off The output power supply is disconnected waiting for the defect to be repaired once thedefectisrepaired pressanybutton COmode the pump has been switched off CUmode thepumphasbeenswitchedoff waiting for the defect to be repaired rep...

Page 9: ...he controller in the mode CO work with a CH pump CH boiler temperature sensor pump L N yellow green wire blue wire brown wire Switching the controller off In order to switch the controller off press and hold for 2 seconds the button the display is then switched off and the green LED changes its colortored The controller is switched off but the GUARD function continues to be active 230V ched off re...

Page 10: ...on ź Theo solve Dispo 10 Wiring diagram of the controller in the mode CU work with a DHW pump Gas boiler Pump DHW sensor DHW tank 230V Wiring diagram with a DHW tank DHW tank Pump 230V temperature sensor fix it with a band HW hot water CW cold water Wiring diagram of a DHW circuit ...

Page 11: ...vicewithliquidsandmoisture ź Donottouchthedisplaywithsharpobjects ź Theoutsideofthecontrollermustbecleanedwithacleancloth Donotuse solvents suchasbenzene thinners oralcohol Disposal of the device The device is marked with a symbol of a crossed waste bin Pursuant to European Directive 2002 96 EC and to the Act on waste electrical and electronic equipment such mark indicates that the device at the e...

Page 12: ...www auraton pl ver 20181130 ...

Reviews: