9
Cooperation of the AURATON RT receiver with the
AURATON R25 RT regulator and/or the AURATON T-2 thermometer
The operation of temperature regulation in the receiver is based on the binary algorithm
(on/off) using one or two sensor elements.
•
The AURATON R25 RT regulator allows for setting and/or monitoring the temperature.
•
The AURATON T-2 thermometer provides information about the current temperature
only, without the capability of changing it manually.
A)
The manual setpoint – pairing the AURATON R25 RT regulator with the RT receiver
allows for setting the temperature manually and controlling it in the location of the
fastening of the R25 RT regulator.
B)
The remote setpoint – if the T-2 thermometer is additionally paired with the RT receiver,
the AURATON R25 RT regulator retains the capability of temperature setting, however
its control is performed with the paired T-2 thermometer only. This feature allows for
regulating the temperature in a room other than the one where the AURATON R25 RT
regulator is placed.
An example: you want the temperature in the “children’s room” to be always at 22°C,
however you do not want children to be able to change it - in that room, you install the
T-2 thermometer, and the AURATON R25 RT regulator in e.g. the kitchen. This way the
temperature in the “children’s room” will always be at 22°C regardless of temperature
fluctuations in the kitchen.
C)
The factory setpoint (20°C) – if the T-2 thermometer is the only device paired with
the RT receiver, it is not possible to set the temperature manually, and the RT receiver
maintains the factory temperature setpoint of 20°C.
NOTE!
1.
The sequence of pairing the AURATON R25 RT regulator and the T-2 thermometer
is very important. If you want to maintain the remote setpoint, you must first pair
the AURATON R25 RT with the RT receiver, and then the T-2 thermometer. Reversing
the pairing sequence will cause automatic deregistering of the previously paired T-2
thermometer and entering the mode of operation described in item A.
2.
The RT receiver can operate with one AURATON R25 RT regulator and/or one T-2
thermometer only. Pairing a new regulator causes deregistering the previously
paired regulator and the T-2 thermometer. Pairing a new T-2 thermometer causes
deregistering the previously paired T-2 thermometer only.
3.
The R25 RT regulator and/or the T-2 thermometer can operate with an unlimited
number of receivers, e.g. one regulator can simultaneously control two independent
heating devices.